After completing this Alaska-approved course, the participant will be able to apply the 100 most important changes from the first half of the 2023 National Electrical Code in common wiring practice.
Course ID(s): 19319
Approved By: Department of Labor and Workforce Development - Reg. of Electrical Administrator
- 2023 NEC Changes Part 1
- Chapter 1 [22 Activities]
- 01. 100. Definitions. Scope.
- 02. 100 Definitions. Attachment Fitting, Weight-Supporting (WSAF). & Receptacle, Weight-Supporting Ceiling (WSCR).
- 03. 100 Definitions. Class 4 Circuit, Class 4 Device, Class 4 Power System, Class 4 Receiver, Class 4 Transmitter, Class 4 Utilization Equipment.
- 04. 100 Definitions. Cord Connector.
- 05. 100 Definitions. Counter (Countertop)
- 06. 100 Definitions. Ground Fault Circuit Interrupter, Special Purpose.
- 07. 100. Definitions.?Ground-Fault Detector-Interrupter, dc (GFDI)?
- 08. 100 Grounding Conductor, Impedance.
- View Additional Activities
- 09. 100 Definitions. Grounded System, Impedance.
- 10. 100 Definitions. Panelboard, Enclosed. ??(Enclosed Panelboard)
- 11. 100 Definitions. Restricted Industrial Establishment.
- 12. 100 Definitions. Stored-Energy Power Supply System (SEPSS).
- 13. 100 Definitions. Work Surface.
- 14. 110.3(A)(8). Examination. Cybersecurity.
- 15. 110.3(B) 110.3(B) Installation and Use.
- 16. 110.16(B) Service Equipment and Feeder Supplied Equipment.
- 17. 110.17. Servicing and Maintenance of Equipment. ??
- 18. 110.20 Reconditioned Equipment. ??
- 19. 110.26 Spaces About Electrical Equipment.
- 20. 110.26(A)(6) Grade, Floor, or Working Platform.
- 21. 110.29 In Sight From (Within Sight From, Within Sight)
- 22. 110.33(A) Entrance to Enclosures and Access to Working Space. Entrance.
- Chapter 2 [53 Activities]
- 01. Article 210, Branch Circuits Not Over 1000 Volts ac, 1500 Volts dc, Nominal.
- 02. 210.2 Reconditioned Equipment
- 03. 210.5(C)(1) Branch Circuits Supplied from More than One Nominal Voltage System.
- 04. 210.8(A)(5) GFCI Protection for Personnel. Dwelling Units. Basements
- 05. 210.8(A)(6) GFCI Protection for Personnel. Dwelling Units. Kitchens ??
- 06. 210.8(A)(7) GFCI Protection for Personnel. Dwelling Units. Areas with Sinks
- 07. 210.8(B). GFCI Protection for Personnel. Other Than Dwelling Units.
- 08. 210.8(B) GFCI Protection for Personnel. Other Than Dwelling Units. Exceptions.
- View Additional Activities
- 09. 210.8(D) GFCI Protection for Personnel. Specific Appliances.
- 10. 210.8(F) GFCI Protection for Personnel. Outdoor Outlets ??
- 11. 210.11(C)(4) Dwelling Units. Garage Branch Circuits.
- 12. 210.12 Arc-Fault Circuit-Interrupter Protection
- 13. 210.17 Guest Rooms and Guest Suites.
- 14. 210.18. Branch-Circuit Ratings. Rating
- 15. 210.23 Permissible Loads, Multiple-Outlet Branch Circuits.
- 16. Table 210.24(1) Summary of Branch-Circuit Requirements - Copper Conductors.
- 17. 210.52(A)(2). General Provisions. Wall Space.
- 18. 210.52(C)(1). Countertops & Work Surfaces. Wall Spaces.
- 19. 210.52(C)(2). Countertops & Work Surfaces. Island and Peninsular Countertops and Work Surfaces.
- 20. 210.52(C)(3) Receptacle Outlet Location.
- 21. 210.52(D) Bathrooms
- 22. 210.70 Lighting Outlets Required.
- 23. 210.70(A)(1) Dwelling Units. Habitable Rooms, Kitchens, Laundry Areas, and Bathrooms. Additional Locations
- 24. 215.15 Barriers.
- 25. 215.18 Surge Protection.
- 26. 220.41 Dwelling Unit(s). Minimum Unit Load.
- 27. 220.42 Lighting Load for Non-Dwelling Occupancies.
- 28. 220.57 Electric Vehicle Supply Equipment (EVSE) Load.
- 29. 220.110 Health Care Facilities. Receptacle Loads.
- 30. 220.120 Marinas. Receptacle Loads.
- 31. Article 225, Outside Branch Circuits and Feeders.
- 32. 225.41 Emergency Disconnects
- 33. 225.42. Surge Protection.
- 34. 230.7 Other Conductors.
- 35. 230.24(A) Clearances. Above Roofs.
- 36. 230.30(B) Wiring Methods.
- 37. 230.62(C) Barriers.
- 38. 230.67. Surge Protection.
- 39. 230.71(B) Two to Six Service Disconnecting Means.
- 40. 230.85 Emergency Disconnects
- 41. Article 235, Branch Circuits, Feeders, and Services Over 1000 Volts ac, 1500 Volts dc, Nominal.
- 42. 240.4(B) Overcurrent Devices Rated 800?Amperes or Less
- 43. 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers
- 44. 242.9. Indicating
- 45. Article 245, Overcurrent Protection for Systems Rated Over 1000 Volts ac, 1500 volts dc.
- 46. 250.64(G) Enclosures with Ventilation Openings.
- 47. 250.68(C) Grounding Electrode Conductor Connections.
- 48. 250.118 Types of Equipment Grounding Conductors.
- 49. 250.130 Equipment Grounding Conductor Connections.
- 50. 250.130(C) Replacement of Nongrounding Receptacle or Snap Switch and Branch Circuit Extensions.
- 51. 250.140 Frames of Ranges and Clothes Dryers.
- 52. 250.148 Continuity of Equipment Grounding Conductors and Attachment in Boxes.
- 53. 250.186 Grounding Service-Supplied Alternating-Current Systems.
- Chapter 3 [15 Activities]
- 01. 300.4(E) Cables, Raceways, or Boxes Installed in or Under Metal-Corrugated Roof Decking.
- 02. Table 300.5(A) Minimum Cover Requirements, 0 to 1000 Volts ac, 1500 Volts dc, Nominal.
- 03. Article 305, General Requirements for Wiring Methods and Materials for Systems Rated Over 1000 volts ac, 1500 volts dc, Nominal.
- 04. 310.15(B)(2). Rooftop.
- 05. 312.10 Screws or Other Fasteners.
- 06. 314.27(E) Weight-Supporting Ceiling Receptacles (WSCR) and Weight-Supporting Attachment Fittings (WSAF).
- 07. 314.29(B) Underground.
- 08. 334.10 Uses Permitted.
- View Additional Activities
- 09. 334.15(B) Protection from Physical Damage.
- 10. 334.40(B) Boxes and Fittings. Devices of Insulating Material.
- 11. 344.28 Reaming and Threading.
- 12. 352.10 Uses Permitted.
- 13. 352.44 Expansion Fittings.
- 14. Article 369, Insulated Bus Pipe (IBP)/Tubular Covered Conductors (TCC) Systems.
- 15. Article 371, Flexible Bus Systems.
- Chapter 4 [10 Activities]
- 01. 404.1 Switches. Scope.
- 02. 404.2(C) Switches Controlling Lighting Loads.
- 03. 404.14(D) Snap Switch Terminations.
- 04. 404.16 Reconditioned Equipment
- 05. 404.30 Switch Enclosures with Doors.
- 06. 406.3(D) Receptacle Terminations.
- 07. 406.4(G). Protection of Floor Receptacles. ??
- 08. 406.6(D) Receptacle Faceplate (Cover Plates) with Integral Night Light and/or USB Charger.
- 09. 406.9(A),(B) Damp Locations, Wet Locations.
- 10. 406.9(C) Bathtub and Shower Space.