The following learning objectives are covered in this class:

  • Describe the overall layout of the National Electrical Code and the addition of new articles.
  • Identify the scope of what is covered and not covered in the Code.
  • List which chapters can supplement or modify other chapters.
  • Identify updates, additions, and changes to Chapter 1 of the 2023 National Electrical Code.
  • Describe changes in the way terms are presented in Article 100, Definitions.
  • Define 12 terms that are newly defined in the 2023 NEC.
  • Outline changes to the general requirements for electrical installations found in Chapter 110 of the 2023 NEC.
  • Identify updates, additions, and changes to Chapter 2 of the 2023 National Electrical Code.
  • Describe changes for branch circuits found in Chapter 2 of the 2023 NEC.
  • Identify changes to branch-circuit requirements as summarized in Tables 210.24(1) and 210.24(2).
  • Outline new requirements covering barriers and surge protection for feeders found in Chapter 2 of the 2023 NEC.
  • Identify changes to branch-circuit, feeder, and service load calculations found in Chapter 2 of the 2023 NEC.
  • List new requirements in Chapter 2 of the 2023 NEC for health care facilities, electric vehicle charging stations, marinas, and docking facilities.
  • Identify the changes to minimum unit load requirements for dwelling units and lighting loads for non-dwelling occupancies found in Chapter 2 of the 2023 NEC.
  • Describe changes to emergency disconnects and surge protection for outside branch circuits and feeders found in Chapter 2 of the 2023 NEC.
  • Outline the new wiring method for installing underground service conductors.
  • List the locations that must be provided with surge protection devices.
  • Identify changes for service conductors and service installation requirements found in Chapter 2 of the 2023 NEC.
  • Outline the new declaration regarding standard overcurrent device ratings found in Chapter 2 of the 2023 NEC.
  • Identify changes to the standard ampere ratings in Table 240.6(A).
  • Describe the new requirement that surge protection devices indicate they are functioning properly.
  • Summarize the new requirements for overcurrent protection requirements for systems over 1000 volts ac, 1500 volts dc in Article 245.
  • Identify the new requirements for grounding and bonding in Chapter 2 of the 2023 NEC.
  • Identify updates, additions, and changes to Chapter 3 of the 2023 National Electrical Code.
  • Summarize the general requirements for wiring methods and materials for systems rated over 1000 volts ac, 1500 volts dc covered in Article 305.
  • Describe changes and additions to the exceptions for cables, raceways, or boxes installed in or under metal-corrugated roof decking found in Chapter 3 of the 2023 NEC.
  • Outline new requirements for installing screws and other fasteners in cabinets, cutout boxes, and meter socket enclosures found in Chapter 3 of the 2023 NEC.
  • Identify additions and changes to requirements for outlet boxes, underground boxes, and handhole enclosures found in Chapter 3 of the 2023 NEC.
  • Outline new requirements for insulated bus pipe and flexible bus systems found in Chapter 3 of the 2023 NEC.
  • List changes to uses permitted and not permitted for nonmetallic-sheathed cable.
  • Identify changed requirements for use and installation of rigid polyvinyl chloride conduit (PVC) found in Chapter 3 of the 2023 NEC.
  • Identify updates, additions, and changes to Chapter 4 of the 2023 National Electrical Code.
  • Describe the change in scope to Chapter 4 of the 2023 NEC.
  • Identify changes and additions to requirements for switches found in Chapter 4 of the 2023 NEC.
  • List new locations requiring tamper-resistant receptacles.
  • Outline new requirements ...

Course ID(s): 0802707

Approved By: Electrical Contractor's Licensing Board (ECLB)

  • 2023 NEC
    • Chapter 1 [8 Activities]
      • 01. 100 Definitions. Ground Fault Circuit Interrupter, Special Purpose.
      • 02. 100. Definitions. Ground-Fault Detector-Interrupter, dc (GFDI)
      • 03. 100 Definitions. Panelboard, Enclosed. (Enclosed Panelboard)
      • 04. 100 Definitions. Restricted Industrial Establishment.
      • 05. 100 Definitions. Stored-Energy Power Supply System (SEPSS).
      • 06. 110.3(A)(8). Examination. Cybersecurity.
      • 07. 110.16(B) Service Equipment and Feeder Supplied Equipment.
      • 08. 110.17. Servicing and Maintenance of Equipment. ??
    • Chapter 2 [24 Activities]
      • 01. 210.8(A)(5) GFCI Protection for Personnel. Dwelling Units. Basements
      • 02. 210.8(A)(6) GFCI Protection for Personnel. Dwelling Units. Kitchens
      • 03. 210.8(A)(7) GFCI Protection for Personnel. Dwelling Units. Areas with Sinks
      • 04. 210.8(B). GFCI Protection for Personnel. Other Than Dwelling Units.
      • 05. 210.8(B) GFCI Protection for Personnel. Other Than Dwelling Units. Exceptions.
      • 06. 210.8(D) GFCI Protection for Personnel. Specific Appliances.
      • 07. 210.8(F) GFCI Protection for Personnel. Outdoor Outlets
      • 08. 210.11(C)(4) Dwelling Units. Garage Branch Circuits.
      • Additional Activities
        • 09. 210.12 Arc-Fault Circuit-Interrupter Protection
        • 10. 210.18. Branch-Circuit Ratings. Rating
        • 11. 210.23 Permissible Loads, Multiple-Outlet Branch Circuits.
        • 12. Table 210.24(1) Summary of Branch-Circuit Requirements - Copper Conductors.
        • 13. 210.52(A)(2). General Provisions. Wall Space.
        • 14. 210.52(C)(1). Countertops & Work Surfaces. Wall Spaces.
        • 15. 210.52(C)(2). Countertops & Work Surfaces. Island and Peninsular Countertops and Work Surfaces.
        • 16. 210.52(C)(3) Receptacle Outlet Location.
        • 17. 210.70 Lighting Outlets Required.
        • 18. 210.70(A)(1) Dwelling Units. Habitable Rooms, Kitchens, Laundry Areas, and Bathrooms. Additional Locations
        • 19. 220.41 Dwelling Unit(s). Minimum Unit Load.
        • 20. 220.42 Lighting Load for Non-Dwelling Occupancies.
        • 21. 225.41 Emergency Disconnects
        • 22. 230.67. Surge Protection.
        • 23. 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers
        • 24. 242.9. Indicating
    • Chapter 3 [2 Activities]
      • 01. 314.29(B) Underground.
      • 02. 334.40(B) Boxes and Fittings. Devices of Insulating Material.
    • Chapter 4 [11 Activities]
      • 01. 404.14(D) Snap Switch Terminations.
      • 02. 406.3(D) Receptacle Terminations.
      • 03. 406.4(G). Protection of Floor Receptacles.
      • 04. 406.6(D) Receptacle Faceplate (Cover Plates) with Integral Night Light and/or USB Charger.
      • 05. 406.9(A),(B) Damp Locations, Wet Locations.
      • 06. 406.9(C) Bathtub and Shower Space.
      • 07. 406.12 Tamper-Resistant Receptacles
      • 08. 408.4(B) Source of Supply.
      • Additional Activities
        • 09. 410.10(D) Bathtub and Shower Areas.
        • 10. 410. Part XVII. Special Provisions for Germicidal Irradiation Luminaires.
        • 11. 440.8. Single Machine and Location
    • Chapter 5 [14 Activities]
      • 01. 501.10(A)(2) Class I, Division 1. Flexible Connections
      • 02. Article 512 Cannabis Oil Equipment and Cannabis Oil Systems Using Flammable Materials.
      • 03. 517.6 Patient Care-Related Electrical Equipment.
      • 04. 517.14 Panelboard Bonding
      • 05. 517.20(A) Receptacles and Fixed Equipment.
      • 06. 517.22 Demand Factors.
      • 07. 517.30 Sources of Power.
      • 08. 550.16(C)(1) Exposed Non-Current-Carrying Metal Parts
      • Additional Activities
        • 09. 550.32. Service Equipment.
        • 10. 550.33(A) Feeder Equipment.
        • 11. 551.40(D). Loss of Ground Device.
        • 12. 555.14 Equipotential Planes and Bonding of Equipotential Planes.
        • 13. 555.15??Replacement of Equipment.
        • 14. 555.36(C) Emergency Electrical Disconnect.
    • Chapter 6 [9 Activities]
      • 01. 625.40 Electric Vehicle Branch Circuit.
      • 02. 625.42 Rating.
      • 03. 630.8 Ground-Fault Circuit-Interrupter Protection for Personnel
      • 04. 680.5 Ground-Fault Circuit-Interrupter (GFCI) and Special Purpose Ground-Fault Circuit-Interrupter (SPGFCI) Protection
      • 05. 680.32 Ground-Fault Circuit-Interrupter (GFCI) and Special Purpose Ground-Fault Circuit Interrupter (SPGFCI) Protection Overview
      • 06. 680.54(B),(C) Bonding, Equipotential Bonding of Splash Pads.
      • 07. 680.59 GFCI and SPGFCI Protection for Permanently Installed Nonsubmersible Pumps.
      • 08. 680.83 Equipotential Bonding.
      • 09. 695.1. Fire Pumps. Scope.
    • Chapter 7 [6 Activities]
      • 01. 700.11 Wiring, Class-2 Powered Emergency Lighting Systems.
      • 02. 702.12(B). Portable Generators 15kW or Less.
      • 03. 726 Class 4 Fault-Managed Power Systems
      • 04. 750.6. Listing
      • 05. 760.24(A) Mechanical Execution of Work.
      • 06. 760.33 Supply-Side Overvoltage Protection.
    • Appendices [1 Activities]
      • 01. Annex C, Table C.1 Conduit, Tubing, and Cable Tray Fill Tables for Conductors and Fixture Wires of the Same Size.
  • Course Completion
    • End of Course Affirmation
    • Mandatory Questionnaire
    • Certificate of Completion
    • Expedited Reporting Available
Instructor Image

Instructor Bio

Jerry Durham

Jerry previously served the state of North Carolina as a Level III electrical inspector and provided state-approved electrical training for electrical inspectors at both Alamance County and Guilford County (NC) Community Colleges. Jerry taught the Kentucky state-approved four-year electrical apprenticeship programs offered by the Independent Electrical Contractors (IEC) Trade School and Associated Builders and Contractors (ABC) Trade School, and served the state of Kentucky as a Master Electrician and Louisville Metro Code Enforcement Officer. Jerry is a Certified Distance Education Instructor (CDEI) and NCCER Core and Electrical Curriculum certified instructor. Jerry currently holds North Carolina and ICC electrical inspector accreditations and is recognized by the state of Washington as an approved electrical administrator.