All lesson material focuses on one thing: installing a safe, code-compliant electrical service in accordance with the 2023 NEC.

Instead of treating service installation as a single block of code, you’ll walk through it as a sequence of on-the-job decisions — where the service conductors originate, how they're sized and installed, what equipment protects the service, and how everything gets disconnected safely.

You will end the training by working through practical scenarios that put those decisions into a real installation context.

After completing the lessons, you will be able to:

  • Explain how the NEC's structure applies to service installation work.
  • Locate the relevant NEC sections governing service installations.
  • Apply the code requirements for overhead service conductors.
  • Choose and install service-entrance conductors that meet code.
  • Rate service equipment according to NEC standards.
  • Position and size service disconnecting means correctly.
  • Provide proper overcurrent protection for a service installation.
  • Work through real-world scenarios covering conductor location, equipment rating, conductor selection, disconnects, multiple services, panel identification, and ground-fault protection of equipment (GFPE).

Course Format: Audio & Text

Credit Type: BE, JE, IJE, RJE, ME, RME, CEI

Course ID(s): 962943

Approved By: Department of Safety & Professional Services - Electrician

Installing Services (2023 NEC) [51 Activities]

  • 01. Installing Services
  • 02. Service Basics - 230.1 Scope
  • 03. Service Basics - Article 100 Definitions: Service
  • 04. Overhead Service Conductors - Article 100 Definitions: Overhead Service & Service-Entrance Conductors
  • 05. Overhead Service Conductors - 230.2 Number of Services
  • 06. Overhead Service Conductors - 230.24(A) Clearances Above Roofs
  • 07. Overhead Service Conductors - 230.24(A) Clearances Above Roofs Exception No. 1
  • 08. Overhead Service Conductors - 230.24(A) Clearances Above Roofs Exceptions 2 and 3
  • 09. Overhead Service Conductors - 230.24(B) Vertical Clearance for Overhead Service Conductors
  • 10. Overhead Service Conductors - 230.28 Service Masts as Supports
  • 11. Underground Service Conductors - Article 100 Definitions: Underground Service & Service-Entrance Conductors
  • 12. Underground Service Conductors - 230.32 Protection Against Damage
  • 13. Service-Entrance Conductors - 230.40 Number of Service-Entrance Conductor Sets
  • 14. Service-Entrance Conductors - 230.42 Minimum Size and Ampacity
  • 15. Service-Entrance Conductors - 310.12 Single-Phase Dwelling Services and Feeders
  • 16. Service-Entrance Conductors - 230.43 Wiring Methods for 1000 Volts, Nominal, or Less
  • 17. Service-Entrance Conductors - 230.46 Spliced and Tapped Conductors
  • 18. Service-Entrance Conductors - 230.50 Protection Against Physical Damage
  • 19. Service-Entrance Conductors - 230.54(C) Service Heads and Goosenecks Above Service-Drop or Overhead Service Attachment
  • 20. Service Equipment - Article 100 Definitions Service Equipment
  • 21. Service Equipment - 230.66 Service Rated Equipment
  • 22. Service Equipment; Disconnecting Means - 230.70(A) Location
  • 23. Service Equipment; Disconnecting Means - 230.70(B)&(C) Marking; Suitable for Use
  • 24. Service Equipment; Disconnecting Means - 230.71 Maximum Number of Disconnects
  • 25. Service Equipment; Disconnecting Means - 230.72 Grouping of Disconnects
  • 26. Service Equipment; Disconnecting Means - 230.79 Rating of Service Disconnecting Means
  • 27. Service Equipment; Disconnecting Means - 230.80 Combined Rating of Disconnects
  • 28. Service Equipment; Disconnecting Means - 230.82 Equipment Connected to the Supply Side of Service Disconnect
  • 29. Service Equipment; Overcurrent Protection - 230.90 Where Required
  • 30. Service Equipment; Overcurrent Protection - 230.91 Location
  • 31. Service Equipment; Overcurrent Protection - 230.95 Ground-Fault Protection of Equipment
  • 32. Strip Shopping Center - Practical Problem #1: Location of the 277/480-Volt Service
  • 33. Strip Shopping Center Practical Problem #2: Location of the 120/208 Volt Service
  • 34. Strip Shopping Center Practical Problem #3: The Rating of the 277/480-Volt Service
  • 35. Strip Shopping Center Practical Problem #4: The Rating of the 120/208-Volt Service
  • 36. Strip Shopping Center Practical Problem #5: Ungrounded Conductors to Tenant Spaces A, B, D, E and G
  • 37. Strip Shopping Center Practical Problem #6: Grounded Conductor to Tenant Spaces A, B, D, E and G
  • 38. Strip Shopping Center Practical Problem #7: Ungrounded Conductors to Tenant Space C (Sandwich Shop)
  • 39. Strip Shopping Center Practical Problem #8: Grounded Conductor to Tenant Space C (Sandwich Shop)
  • 40. Strip Shopping Center Practical Problem #9: Ungrounded Conductor to Tenant Space H (Print Shop)
  • 41. Strip Shopping Center Practical Problem #10: Grounded Conductor to Tenant Space H (Print Shop)
  • 42. Strip Shopping Center Practical Problem #11: Ungrounded Conductor to Tenant Space F (Restaurant)
  • 43. Strip Shopping Center Practical Problem #12: Grounded Conductors in Parallel
  • 44. Strip Shopping Center Practical Problem #13: Location of the 120/208-Volt Service
  • 45. Strip Shopping Center Practical Problem #14: Conduit Installation to Tenant Spaces
  • 46. Strip Shopping Center Practical Problem #15: Location of Service Disconnects
  • 47. Strip Shopping Center Practical Problem #16: Two Services
  • 48. Strip Shopping Center Practical Problem #17: House Load Panel
  • 49. Strip Shopping Center Practical Problem #18: Identifying Service Location
  • 50. Strip Shopping Center Practical Problem #19: Service Requirements in the NEC
  • 51. Strip Shopping Center Practical Problem #20: Ground-Fault Protection

Course Completion

  • Mandatory Questionnaire
  • Certificate of Completion
Instructor Image

Instructor Bio

Jerry Durham

Jerry previously served the state of North Carolina as a Level III electrical inspector and provided state-approved electrical training for electrical inspectors at both Alamance County and Guilford County (NC) Community Colleges. Jerry taught the Kentucky state-approved four-year electrical apprenticeship programs offered by the Independent Electrical Contractors (IEC) Trade School and Associated Builders and Contractors (ABC) Trade School, and served the state of Kentucky as a Master Electrician and Louisville Metro Code Enforcement Officer. Jerry is a Certified Distance Education Instructor (CDEI) and NCCER Core and Electrical Curriculum certified instructor. Jerry currently holds North Carolina and ICC electrical inspector accreditations and is recognized by the state of Washington as an approved electrical administrator.