Explore some of the most significant additions and reorganizations introduced in the 2026 National Electrical Code (NEC), and how they affect everyday installation practices and jobsite safety.
The 6-hour online training simplifies complex code updates into practical, easy-to-follow concepts.
You’ll learn how the revisions impact:
- Definitions and code organization
- Equipment listing, identification markings, arc-flash labeling, and working space standards
- Branch-circuit, feeder, and service load calculations for dwelling units and EV supply equipment
- Energy management systems, grounded conductor identification, and signaling circuits
- GFCI, SPGFCI, and ground-fault protection applications in residential and commercial settings
- Conductor sizing, ampacity tables, raceways, wiring devices, switches, and panelboards
- HVAC systems, generators, hazardous locations, marinas, EV systems, emergency power, and communications infrastructure
Upon successful completion, you’ll be prepared to interpret and apply the latest NEC standards across all your projects.
Approved By: Sedgwick County Metropolitan Building & Construction Department - Electrical
2026 NEC: Top 75 Changes
Chapter One [24 Activities]
- 01. Introduction to the 2026 NEC, Overview
- 02. New Articles & Global Changes
- 03. 90.3 Code Arrangement.
- 04. 100 Definitions. Artificially Ventilated Room "v"
- 05. 100 Definitions. Bonding Conductor, Grounding Electrode (Grounding Electrode Bonding Jumper). (Grounding Electrode Bonding Conductor)
- 06. 100 Definitions. Cable, Limited-Energy. (Limited-Energy Cable)
- 07. 100 Definitions. Ground-Fault Circuit Interrupter, Special Purpose Ground-Fault Circuit Interrupter (SPGFCI).
- 08. 100 Definitions. Ground-Fault Circuit Interrupter, Special Purpose, Classes C, D, and E Devices
- 09. 100 Definitions. Hand Fastened.
- 10. 100 Definitions. Lampholder.
- 11. 100 Definitions. Transformer Secondary Conductor
- 12. 110.10 Available Fault Current, Short-Circuit Current Ratings, and Other Characteristics
- 13. 110.15 High-Leg Marking
- 14. 110.16 Arc-Flash Hazard Marking.
- 15. 110.17 Servicing of Equipment
- 16. 110.26 Spaces About Electrical Equipment.
- 17. 110.26(A)(1) Depth of Working Space
- 18. 110.34 Work Space and Guarding. Table 110.34(A) Minimum Working Space. Over 1000VAC, 1500VDC.
- 19. 120 Branch-Circuit, Feeder, and Service Load Calculations.
- 20. 120.41 Dwelling Units, Minimum Unit Load
- 21. 120.57 Electric Vehicle Supply Equipment (EVSE) Load
- 22. 120.82 Dwelling Unit. Optional Feeder and Service Load Calculations.
- 23. 120.83 Existing Dwelling Unit (Calculations and Load Percentages).
- 24. 130 Energy Management Systems
Chapter Two [11 Activities]
- 01. 200.7(A)(9) Means of Identifying Grounded Conductors. Sizes 6 AWG or smaller
- 02. 206 Non-Power-Limited Remote-Control and Signaling Circuits
- 03. 210.8 GFCI Protection. Exception (applicable to all installations)
- 04. 210.8 (A)(3) Ground-Fault Circuit-Interrupter Protection for Personnel. Accessory Buildings.
- 05. 210.13(B) Ground-Fault Protection of Equipment. Solidly Grounded dc Electrical Systems
- 06. 210.23(A) Permissible Loads, Multiple-Outlet Branch Circuits. 10-Ampere Branch CIrcuits
- 07. 210.52(A)(5) Dwelling Unit Receptacle Outlets. Prohibited Locations (Countertops versus Wall Space)
- 08. 210.70 Lighting Outlets Required—Battery Operated Switches
- 09. 210.70 (A)(1) LIghting Outlets Required. Dwelling Units. Laundry Areas
- 10. 240.7 Overcurrent Protective Devices
- 11. 270 Grounding and Bonding of Systems over 1000VAC, 1500VDC, Nominal
Chapter Three [5 Activities]
- 01. 300.4(C) Damaged Conductors and Wiring Methods
- 02. 310.5(A) [16 AWG Copper] Conductors for General Wiring. Minimum Size of Conductors
- 03. 310.5(A) [14 AWG Copper-Clad Aluminum] Conductors for General Wiring. Minimum Size of Conductors
- 04. 310.16 [Table 310.16]. Ampacities of Insulated Conductors in Raceway, Cable, or Earth (Directly Buried).
- 05. 352.20(B) Rigid Polyvinyl Chloride Conduit (PVC). Maximum Size
Chapter Four [18 Activities]
- 01. 402.5 Ampacities for Fixture Wires.
- 02. 404.1 Switches. Scope
- 03. 406.1 Wiring Devices [Formerly Known as Receptacles, Cord Connectors, and Attachment Plugs (Caps)]. Scope
- 04. 406.12(D)(3) Wiring Devices [Formerly Known as Receptacles, Cord Connectors, and Attachment Plugs (Caps)] - Replacement - GFCI Protection
- 05. 406.40(D) Wiring Devices. General-Use Snap Switches, Dimmers, and Control Switches. Faceplates or Cover Plates Incorporating Night Lights, USB Chargers, or Both.
- 06. 408.6 Switchboards, Switchgear, and Panelboards. Short-Circuit Current Rating.
- 07. 422.5 Appliances. GFCI Protection
- 08. 422.12 Appliance. Central Heating Equipment
- 09. 424.2 Fixed Electric Space-Heating Equipment. Listing Requirements
- 10. 424.3 Fixed Electric Space-Heating Equipment. Reconditioned Equipment
- 11. 426 Fixed Outdoor Electric Deicing and Snow-Melting Equipment. Part VI. Conductive Pavement Heating Systems
- 12. 430.22(H) Single Motors. Design BE and CE Motors.
- 13. 440.2 Air-Conditioning and Refrigerating Equipment. Listing Requirements.
- 14. 440.4(A) Air-Conditioning and Refrigerating Equipment. Hermetic Refrigerant Motor-Compressor Nameplate.
- 15. 440.14 Air-Conditioning and Refrigerating Equipment. Location.
- 16. 440.15 Air-Conditioning and Refrigerating Equipment. Split-System Indoor Unit Identification
- 17. 445.13 Generators. Conductors - Minimum Ampacity and Size.
- 18. 480.8 Grounding of Battery Stands and Conductive Cases.
Chapter Five [4 Activities]
- 01. 500.7 Hazardous (Classified) Locations. Protection Techniques
- 02. 500.30 Bonding in Hazardous (Classified) Locations.
- 03. 512.3 Cannabis Oil Equipment and Cannabis Oil Systems Using Flammable Materials
- 04. 555.9 Marinas, Boatyards, Floating buildings, and Docking Facilities. Engineered Design
Chapter Six [6 Activities]
- 01. 620.51(E) Elevators, Dumbwaiters, etc. Surge Protection
- 02. 624 Electric Self-Propelled Vehicle Power Transfer Systems (ESVSEs)
- 03. 625.4 Electric Vehicle Power Transfer System. Qualified Person
- 04. 625.5 Electric Vehicle Power Transfer System. Field Markings
- 05. 695.7(A)(2) Fire Pumps. Supply Conductors. Feeders
- 06. 695.14(F) Fire Pumps. Generator Control Wiring Methods
Chapter Seven [6 Activities]
- 01. 700. Chapter 7 Title Change: Specific Conditions and Systems
- 02. 700.1 Emergency Systems. Scope
- 03. 700.4 Commissioning and Servicing.
- 04. 700.4(F)(8) Emergency Systems. Temporary Source of Power During Servicing (Equal Protection)
- 05. 700.4(F)(9) Emergency Systems. Temporary Source of Power During Servicing (Switching Separately Derived Systems).
- 06. 700.10(D)(2) Emergency System. Fire Protection. Feeder-Circuit Wiring
Chapter Eigth [2 Activities]
- 01. 800.1 General Requirements for Communications Systems Outside and Entering Buildings. Scope
- 02. 800.44 Communications Systems. Overhead (Aerial) Wires and Cables
Course Completion
Mandatory Questionnaire
Certificate of Completion

