This course is accepted for Kansas electricians and counts as 12 hours of continuing education.
After completing this course the participant will be able to apply the changes to the 2020 National Electrical Code in common wiring practice.
Approved By: Sedgwick County Metropolitan Building & Construction Department - Electrical
- 2020 NEC Changes
- Checkpoint 1
- Introduction and Chapter 1 [14 Activities]
- 01. 90.2 Scope. (A) Covered.
- 02. 100 Definitions - Accessible
- 03. 100 Definitions- Attachment Fitting
- 04. 100 Definitions - Dormitory Unit
- 05. 100 Definitions - Equipotential Plane
- 06. 100 Definitions - Fault Current, Fault Current Available
- 07. 100 Definitions - Grounded Conductor
- 08. 100 Definitions - Habitable Room
- Additional Activities
- 09. 100 Definitions - Island Mode
- 10. 100 Definitions - Labeled
- 11. 100 Definitions - Reconditioned
- 12. 110.22 Requirements for Electrical Installations. Identification of Disconnecting Means
- 13. 110.26(A)(3) Height of Working Space
- 14. 110.26(C)(2) Large Equipment
- Checkpoint 2
- Chapter 2 [38 Activities]
- 01. 200.10(B) Identification of Terminals.
- 02. 210.5(C)(1) Branch Circuits Supplied from More than one Nominal Voltage System
- 03. 210.8(A) Branch Circuits. Ground Fault Circuit-Interrupter (GFCI) Protection. Dwelling Units.
- 04. 210.8(B) GFCI Protection for Personnel. Other than Dwelling Units.
- 05. 210.8(C) Crawl Space Lighting Outlets.
- 06. 210.8(D) Specific Appliances.
- 07. 210.8(E) Equipment Requiring Servicing
- 08. 210.11(C)(3) Bathroom Branch Circuits
- Additional Activities
- 09. 210.11(C)(4) Garage Branch Circuits
- 10. 210.12(A)(5) AFCI - Dwelling Units (C), (D)
- 11. 210.15 Reconditioned Equipment
- 12. 210.52(C) Countertops and Work Surfaces
- 13. 210.52(C)(1) Wall Spaces
- 14. 210.52(C)(2) Island and Peninsular Countertops and Work Surfaces
- 15. 210.52 (E)(3) Receptacle Outlet for Balconies, Decks, and Porches
- 16. 220.12 and Table 220.12 - Lighting Load for Non dwelling Occupancies
- 17. 220.14(J) Unit Loads for Dwelling Units
- 18. 220.53 Appliance Load- Dwelling Units
- 19. 225.10 Wiring on Buildings (or Other Structures).
- 20. 230.46 Spliced and Tapped Conductors
- 21. 230.62(C). Services. Service Equipment General. Service Equipment Enclosed or Guarded. Barriers.
- 22. 230.71 Maximum Number of Disconnects
- 23. 230.85 Emergency Disconnects
- 24. Sections 240.62 - 240.88 - 240.102 Reconditioned Equipment
- 25. 240.87 Arc Energy Reduction
- 26. 242 Overvoltage Protection
- 27. 250 Grounding and Bonding
- 28. 250.25 Grounding and Bonding. Grounding Systems Permitted to be Connected on the Supply Side of the Disconnect
- 29. 250.53(C) Grounding and Bonding. Grounding Electrode System Installation. Bonding Jumper
- 30. 250.64(A) Grounding and Bonding. Grounding Electrode Conductor. Aluminum or Copper Clad Aluminum Conductors
- 31. 250.64(B)(2) & (B)(3) Grounding Electrode Conductor Protection from Physical Damage
- 32. 250.104(A)(1) and (A)(3) Bonding Jumpers
- 33. 250.109 Metal Enclosures
- 34. 250.119 Identification of Equipment Grounding Conductor
- 35. 250.121(B) Restricted Use of Metal Frames
- 36. 250.122 Size of Equipment Grounding Conductor Increased in Size
- 37. Table 250.122 Minimum Size Equipment Grounding Conductors for Grounding Raceway and Equipment
- 38. 250.148 Continuity of Equipment Grounding Conductor and Attachment in Boxes
- Checkpoint 3
- Chapter 3 [13 Activities]
- 01. 300.15(F) Boxes, Conduit Bodies, or Fittings - Where Required. Fitting.
- 02. 300.25 Exit Enclosures (Stair Towers)
- 03. 300.45 Danger Signs.
- 04. 310.4 Conductor Constructions and Applications
- 05. 310.12, Table, Dwelling Unit Service and Main Power Feeder Conductors
- 06. 310.15 Ampacity Tables
- 07. 311 Medium Voltage Conductors and Cables
- 08. 314.16(B)(5) Equipment Grounding Conductor Fill
- Additional Activities
- 09. 314.27(C) Boxes at Ceiling-Suspended Paddle Fan Outlets
- 10. 320.80(A) Ampacity. Thermal Insulation.
- 11. 337 Type P Cable
- 12. 338.100 Construction.
- 13. 380.12(7) Multioutlet Assembly. Uses Not Permitted.
- Checkpoint 4
- Chapter 4 [28 Activities]
- 01. 404.9 General Use Snap Switches, Dimmers, and Control Switches
- 02. 404.14 (A), (B), (C), (D) Rating and Use of Switches
- 03. 406.3(A) Receptacle Rating and Type. Receptacles
- 04. 406.4(D)(4) Replacements. AFCI Protection
- 05. 406.4(D)(7) Replacements. Controlled Receptacles.
- 06. 406.5(G)(2) Receptacle Orientation. Under Sinks.
- 07. 406.9(C) Receptacles in Damp or Wet Locations. Bathtub and Shower Space.
- 08. 406.12 Tamper Resistant Receptacles
- Additional Activities
- 09. 406.13 Single Pole Separable Connector Type
- 10. 408.4(A) Field Identification Required. Circuit Directory or Circuit Identification.
- 11. 408.6 Switchboards/Panelboards. Short-Circuit Current Rating.
- 12. 408.8 Switchboards/Panelboards. Reconditioning of Equipment.
- 13. 408.18(C)(2) Clearances. Connections. Grounded Circuit Conductors.
- 14. 408.43 Panelboard Orientation
- 15. 410 Luminaires, Lampholders and Lamps. Part XVI- Special Provisions for Horticultural Lighting Equipment.
- 16. 410.2&16 Luminaires, Lampholders, and Lamps. Luminaires in Clothes Closets.
- 17. 410.7 Luminaires, Lampholders, and Lamps. Reconditioned Equipment.
- 18. 410.36(A) Luminaires/Lamps. Means of Support.
- 19. 410.69 Luminaires/Lamps. Identification of Control Conductor Insulation.
- 20. 410.118 Luminaire Access to Other Boxes
- 21. 422.5(A) GFCI Protection for Personnel.
- 22. 430.2 Definitions. Electronically Protected.
- 23. 440.9 Air Conditioning and Refrigeration Equipment. Grounding and Bonding.
- 24. 445.18(D) Generators. Disconnecting Means and Emergency Shutdown.
- 25. 450.9 Transformers. Ventilation.
- 26. 480.7(B),(C),(F),(G) Storage Batteries. DC Disconnect Methods.
- 27. 480.10(C) Storage Batteries. Battery Locations. Spaces About Battery Systems.
- 28. 480.10(E) Storage Batteries. Battery Locations. Egress.
- Checkpoint 5
- Chapter 5 [23 Activities]
- 01. 500.7 (L),(M),(N),(O) Hazardous Locations. Protection Techniques.
- 02. 500.7(O) Hazardous Locations. Protection Techniques.
- 03. 500.8(G) Hazardous (Classified) Locations. Equipment. Equipment Involving Optical Radiation.
- 04. 502.10(A)(2) Class II Locations. Wiring Method. Class II Division 1. Flexible Connections.
- 05. 503.10 (A) Hazardous (Classified) Locations. Class III Locations. Wiring Methods.
- 06. 511.12 Commercial Garages, Repair and Storage. GFCI Protection for Personnel.
- 07. 513.3(D) Aircraft Hangars. Classification of Locations.
- 08. 514.11(A) Motor Fuel Dispensing Facilities. Circuit Disconnects. Emergency Electrical Disconnects.
- Additional Activities
- 09. 517.10(B)(3) Health Care Facilities. Applicability. Not Covered.
- 10. 517.17(D) Health Care Facilities. Ground-Fault Protection of Equipment. Testing.
- 11. 517.26 Health Care Facilities. Essential Electrical System. Application of Other Articles.
- 12. 517.30(B)(3) Sources of Power. Types of Power Sources. Battery Systems.
- 13. 517.31(C)(1) Requirements for the Essential Electrical System. Separation from Other Circuits.
- 14. 518.6 Assembly Occupancies. Illumination.
- 15. 545.24(A),(B) Manufactured Buildings and Relocatable Structures. Disconnecting Means and Branch-Circuit Overcurrent Protection.
- 16. 547.5(G) Agricultural Buildings. Wiring Methods. Receptacles.
- 17. 550.13(B) Mobile Homes, Manufactured Homes, Mobile Home Parks. Receptacle Outlets. GFCI.
- 18. 551.40(D) RVs and RV Parks. 120 V or 120/240 V, Nominal, Systems. Reverse Polarity Device.
- 19. 555 Part III Floating Buildings
- 20. 555.2 Marinas, Boatyards, Floating Buildings and Commercial and Noncommercial Docking Facilities. Definitions.
- 21. 555.9 Marinas, Boatyards, Floating Buildings and Commercial and Noncommercial Docking Facilities. Boat Hoists.
- 22. 555.35(A) Marinas, Boatyards... Ground-Fault Protection of Equipment (GFPE) and GFCI Protection.
- 23. 590.8 Temporary Installations. Overcurrent Protective Devices.
- Checkpoint 6
- Chapter 6 [26 Activities]
- 01. 600.2 Electric Signs and Outline Lighting. Definitions.
- 02. 600.35 Electric Signs and Outline Lighting. Retrofit Kits.
- 03. 605.1 Office Furnishings. Scope.
- 04. 625 and 625.1 Electric Vehicle Power Transfer System. Scope.
- 05. 625.2 Electric Vehicle Power Transfer System. Definitions.
- 06. 625.54 Electric Vehicle Power Transfer System. GFCI Protection for Personnel.
- 07. 625.56 Electric Vehicle Power Transfer System. Receptacle Enclosures.
- 08. 625.60 Electric Vehicle Power Transfer System. AC Receptacle Outlets Used for EVPE.
- Additional Activities
- 09. 680.2 Swimming Pools, Fountains, and Similar Installations. Definitions
- 10. 680.4 Swimming Pools, Fountains, and Similar Installations. Inspections After Installation
- 11. 680.21(C) Swimming Pools, Fountains, and Similar Installations. Motors. GFCI Protection.
- 12. 680.21(D) Swimming Pools, Fountains, and Similar Installations. Motors. Pool Pump Motor Replacement.
- 13. 680.22(A)(5) Swimming Pools, Fountains, and Similar Installations. Lighting, Receptacles, and Equipment. Receptacles.
- 14. 680.22(C) Swimming Pools, Fountains, and Similar Installations. Lighting, Receptacles, and Equipment. Switching Devices. Other Equipment.
- 15. 680.22(E) Swimming Pools, Fountains, and Similar Installations. Lighting, Receptacles, and Equipment. Switching Devices. Other Equipment.
- 16. 680.23(B)(6) Swimming Pools, Fountains, and Similar Installations. Underwater Luminaires. Wet Niche Luminaires. Servicing.
- 17. 680.26(B)(2) and (B)(5) Swimming Pools, Fountains, and Similar Installations. Equipotential Bonding.
- 18. 680.35 Swimming Pools, Fountains, and Similar Installations. Storable and Portable Immersion Pools.
- 19. 680.45 Swimming Pools, Fountains, and Similar Installations. Permanently Installed Immersion Pools
- 20. 680.59 Swimming Pools, Fountains, and Similar Installations. GFCI Protection for Permanently Installed Nonsubmersible Pumps.
- 21. 682.33(C) Natural and Artificially Made Bodies of Water. Bonding of Equipotential Planes.
- 22. 690.2 Solar PV Systems. Definitions. Grounded, Functionally.
- 23. 690.13(A), (E) Solar PV Systems. Photovoltaic System Disconnecting Means. Location. Type of Disconnect.
- 24. 690.33 Solar PV Systems. Mating Connectors.
- 25. 690.41(B). Solar PV Systems. System Grounding. Ground-Fault Protection.
- 26. 690.56(C) Solar PV Systems. Identification of Power Sources. Buildings with Rapid Shutdown.
- Checkpoint 7
- Chapter 7 [8 Activities]
- 01. 700.5(A) Emergency Systems. Transfer Equipment.
- 02. 702.7(A) Optional Standby Systems. Signs. Standby.
- 03. 706.4, .7 Energy Storage Systems. System Requirements. Maintenance.
- 04. 708.24(D) COPS. Bypass Isolation Automatic Transfer Switches.
- 05. 712.2 DC Microgrids. Definitions. Grounded, Functionally.
- 06. 712.10 DC Microgrids. Directory.
- 07. 725.48(B)(1) Class 1, 2, & 3 Remote-Control, Signaling and Power-Limited Circuits. Class 1 Circuits with Power-Supply Circuits. In a Cable, Enclosure, or Raceway.
- 08. 770.24 Optical Fiber cables. Mechanical Execution of Work.
- Final Checkpoint
- Course Completion
- Mandatory Questionnaire
- Certificate of Completion
- Expedited Reporting Available