After completing this Kentucky continuing education, the participant will be able to apply the 67 most important changes to the 2023 National Electrical Code in common wiring practice.

Learning Objectives:

  • Describe the overall layout of the National Electrical Code and the addition of new articles.
  • Identify the scope of what is covered and not covered in the Code.
  • List which chapters can supplement or modify other chapters.
  • Identify updates, additions, and changes to Chapter 1 of the 2023 National Electrical Code.
  • Describe changes in the way terms are presented in Article 100, Definitions.
  • Define terms that are newly defined in the 2023 NEC.
  • Outline changes to the general requirements for electrical installations found in Chapter 110 of the 2023 NEC.
  • Identify updates, additions, and changes to Chapter 2 of the 2023 National Electrical Code.
  • Describe changes for branch circuits found in Chapter 2 of the 2023 NEC.
  • Identify the changes to minimum unit load requirements for dwelling units and lighting loads for non-dwelling occupancies found in Chapter 2 of the 2023 NEC.
  • Describe changes to emergency disconnects and surge protection for outside branch circuits and feeders found in Chapter 2 of the 2023 NEC.
  • Outline the new wiring method for installing underground service conductors.
  • List the locations that must be provided with surge protection devices.
  • Identify changes for service conductors and service installation requirements found in Chapter 2 of the 2023 NEC.
  • Outline the new declaration regarding standard overcurrent device ratings found in Chapter 2 of the 2023 NEC.
  • Identify changes to the standard ampere ratings in Table 240.6(A).
  • Describe the new requirement that surge protection devices indicate they are functioning properly.

Approved By: Department of Housing, Buildings & Construction - Electrical Division

  • 2023 NEC Changes Part 1
    • Chapter 1 [22 Activities]
      • 01. 100. Definitions. Scope.
      • 02. 100 Definitions. Attachment Fitting, Weight-Supporting (WSAF). & Receptacle, Weight-Supporting Ceiling (WSCR).
      • 03. 100 Definitions. Class 4 Circuit, Class 4 Device, Class 4 Power System, Class 4 Receiver, Class 4 Transmitter, Class 4 Utilization Equipment.
      • 04. 100 Definitions. Cord Connector.
      • 05. 100 Definitions. Counter (Countertop)
      • 06. 100 Definitions. Ground Fault Circuit Interrupter, Special Purpose.
      • 07. 100. Definitions.Ground-Fault Detector-Interrupter, dc (GFDI)
      • 08. 100 Grounding Conductor, Impedance.
      • Additional Activities
        • 09. 100 Definitions. Grounded System, Impedance.
        • 10. 100 Definitions. Panelboard, Enclosed. ??(Enclosed Panelboard)
        • 11. 100 Definitions. Restricted Industrial Establishment.
        • 12. 100 Definitions. Stored-Energy Power Supply System (SEPSS).
        • 13. 100 Definitions. Work Surface.
        • 14. 110.3(A)(8). Examination. Cybersecurity.
        • 15. 110.3(B) 110.3(B) Installation and Use.
        • 16. 110.16(B) Service Equipment and Feeder Supplied Equipment.
        • 17. 110.17. Servicing and Maintenance of Equipment.
        • 18. 110.20 Reconditioned Equipment.
        • 19. 110.26 Spaces About Electrical Equipment.
        • 20. 110.26(A)(6) Grade, Floor, or Working Platform.
        • 21. 110.29 In Sight From (Within Sight From, Within Sight)
        • 22. 110.33(A) Entrance to Enclosures and Access to Working Space. Entrance.
    • Chapter 2 [45 Activities]
      • 01. Article 210, Branch Circuits Not Over 1000 Volts ac, 1500 Volts dc, Nominal.
      • 02. 210.2 Reconditioned Equipment
      • 03. 210.5(C)(1) Branch Circuits Supplied from More than One Nominal Voltage System.
      • 04. 210.8(A)(5) GFCI Protection for Personnel. Dwelling Units. Basements
      • 05. 210.8(A)(6) GFCI Protection for Personnel. Dwelling Units. Kitchens
      • 06. 210.8(A)(7) GFCI Protection for Personnel. Dwelling Units. Areas with Sinks
      • 07. 210.8(B). GFCI Protection for Personnel. Other Than Dwelling Units.
      • 08. 210.8(B) GFCI Protection for Personnel. Other Than Dwelling Units. Exceptions.
      • Additional Activities
        • 09. 210.8(D) GFCI Protection for Personnel. Specific Appliances.
        • 10. 210.8(F) GFCI Protection for Personnel. Outdoor Outlets
        • 11. 210.11(C)(4) Dwelling Units. Garage Branch Circuits.
        • 12. 210.12 Arc-Fault Circuit-Interrupter Protection
        • 13. 210.17 Guest Rooms and Guest Suites.
        • 14. 210.18. Branch-Circuit Ratings. Rating
        • 15. 210.23 Permissible Loads, Multiple-Outlet Branch Circuits.
        • 16. Table 210.24(1) Summary of Branch-Circuit Requirements - Copper Conductors.
        • 17. 210.52(A)(2). General Provisions. Wall Space.
        • 18. 210.52(C)(1). Countertops & Work Surfaces. Wall Spaces.
        • 19. 210.52(C)(2). Countertops & Work Surfaces. Island and Peninsular Countertops and Work Surfaces.
        • 20. 210.52(C)(3) Receptacle Outlet Location.
        • 21. 210.52(D) Bathrooms
        • 22. 210.70 Lighting Outlets Required.
        • 23. 210.70(A)(1) Dwelling Units. Habitable Rooms, Kitchens, Laundry Areas, and Bathrooms. Additional Locations
        • 24. 215.15 Barriers.
        • 25. 215.18 Surge Protection.
        • 26. 220.41 Dwelling Unit(s). Minimum Unit Load.
        • 27. 220.42 Lighting Load for Non-Dwelling Occupancies.
        • 28. 220.57 Electric Vehicle Supply Equipment (EVSE) Load.
        • 29. 220.110 Health Care Facilities. Receptacle Loads.
        • 30. 220.120 Marinas. Receptacle Loads.
        • 31. Article 225, Outside Branch Circuits and Feeders.
        • 32. 225.41 Emergency Disconnects
        • 33. 225.42. Surge Protection.
        • 34. 230.7 Other Conductors.
        • 35. 230.24(A) Clearances. Above Roofs.
        • 36. 230.30(B) Wiring Methods.
        • 37. 230.62(C) Barriers.
        • 38. 230.67. Surge Protection.
        • 39. 230.71(B) Two to Six Service Disconnecting Means.
        • 40. 230.85 Emergency Disconnects
        • 41. Article 235, Branch Circuits, Feeders, and Services Over 1000 Volts ac, 1500 Volts dc, Nominal.
        • 42. 240.4(B) Overcurrent Devices Rated 800?Amperes or Less
        • 43. 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers
        • 44. 242.9. Indicating
        • 45. Article 245, Overcurrent Protection for Systems Rated Over 1000 Volts ac, 1500 volts dc.
  • Course Completion
    • Mandatory Questionnaire
    • Certificate of Completion
    • Expedited Reporting Available
Instructor Image

Instructor Bio

Jerry Durham

Jerry previously served the state of North Carolina as a Level III electrical inspector and provided state-approved electrical training for electrical inspectors at both Alamance County and Guilford County (NC) Community Colleges. Jerry taught the Kentucky state-approved four-year electrical apprenticeship programs offered by the Independent Electrical Contractors (IEC) Trade School and Associated Builders and Contractors (ABC) Trade School, and served the state of Kentucky as a Master Electrician and Louisville Metro Code Enforcement Officer. Jerry is a Certified Distance Education Instructor (CDEI) and NCCER Core and Electrical Curriculum certified instructor. Jerry currently holds North Carolina and ICC electrical inspector accreditations and is recognized by the state of Washington as an approved electrical administrator.