This 4-hour training focuses on the 2026 updates to Chapters 1 and 2 of the National Electrical Code (NEC), with emphasis on new definitions, global requirements, and revised safety protocols.
Students will review adjustments to:
- Code arrangements and industry terms
- Equipment examination and installation
- Arc-flash hazard marking and servicing
- Grounded and ungrounded conductors
- Lighting and outlet provisions, including acceptable placement areas
- Permissible loads, energy management, and protection requirements
When finished, participants will be able to implement the latest code standards safely and correctly.
IACET CEUs
These courses gives you the opportunity to earn IACET CEUs through our parent company Certus. As an IACET Accredited Provider, Certus offers IACET CEUs for its learning events that comply with the ANSI/IACET Continuing Education and Training Standard. To earn IACET CEUs, you must:
- Complete all lessons in the course,
- Correctly answer every quiz question posed through the course, and
- Complete the course evaluation.
Assessment Information: This online course presents each section with commentary, a graphic illustration or photograph, and requires the learner to answer multiple choice questions after reviewing the content. The learner must complete all multiple-choice questions for each section correctly to get IACET CEUs, a certificate of completion, or state license renewal credit for the course. If the learner's first response is incorrect, learners will be immediately allowed to answer the question again until the correct answer is chosen. Question choices are randomized, so each participant will have a unique testing experience
Prerequisites: This course has no prerequisites.
Course Format: Video & Text
Credit Type: Electrical Code
CEUs: 0.4
Course ID(s): CRSE2608-0076
Approved By: Department of Labor And Industry - Construction Codes and Licensing Division
1 A 2026 NEC Changes Part 1
- Chapter One [33 Activities]
- 01. Introduction to the 2026 NEC, Overview
- 02. New Articles & Global Changes
- 03. 90.3 Code Arrangement.
- 04. 100 Definitions. Artificially Ventilated Room "v"
- 05. 100 Definitions. Bonding Conductor, Grounding Electrode (Grounding Electrode Bonding Jumper). (Grounding Electrode Bonding Conductor)
- 06. 100 Definitions. Cable, Limited-Energy. (Limited-Energy Cable)
- 07. 100 Definitions. Cannabis Oil: Booths, Extraction, Post-Processing, and Preparatory Equipment and Systems.
- 08. 100 Definitions. Ground-Fault Circuit Interrupter, Special Purpose Ground-Fault Circuit Interrupter (SPGFCI).
- 09. 100 Definitions. Ground-Fault Circuit Interrupter, Special Purpose, Classes C, D, and E Devices
- 10. 100 Definitions. Hand Fastened.
- 11. 100 Definitions. Lampholder.
- 12. 100 Definitions. Service Point, Communications. (Communications Service Point).
- 13. 100 Definitions. Transformer Secondary Conductor
- 14. 100 Definitions. Wiring Device.
- 15. 110.10 Available Fault Current, Short-Circuit Current Ratings, and Other Characteristics
- 16. 110.15 High-Leg Marking
- 17. 110.16 Arc-Flash Hazard Marking.
- 18. 110.17 Servicing of Equipment
- 19. 110.20 Reconditioned Equipment
- 20. 110.26 Spaces About Electrical Equipment.
- 21. 110.26(A)(1) Depth of Working Space
- 22. 110.29 In Sight From (Within Sight From, Within Sight)
- 23. 110.31 Enclosure for Electrical Installations: Table 110.31 Minimum Distance from Fence to Live Parts. Over 1000 VAC, 1500VDC
- 24. 110.34 Work Space and Guarding. Table 110.34(A) Minimum Working Space. Over 1000VAC, 1500VDC.
- 25. 110.39 In Sight From (Within Sight From, Within Sight). Over 1000VAC, 1500VDC.
- 26. 110.40 Electrical Connections. Over 1000VAC, 1500VDC.
- 27. 110.75 Access to Manholes.
- 28. 120 Branch-Circuit, Feeder, and Service Load Calculations.
- 29. 120.41 Dwelling Units, Minimum Unit Load
- 30. 120.57 Electric Vehicle Supply Equipment (EVSE) Load
- 31. 120.82 Dwelling Unit. Optional Feeder and Service Load Calculations.
- 32. 120.83 Existing Dwelling Unit (Calculations and Load Percentages).
- 33. 130 Energy Management Systems
- Chapter Two [16 Activities]
- 01. 200.7(A)(9) Means of Identifying Grounded Conductors. Sizes 6 AWG or smaller
- 02. 206 Non-Power-Limited Remote-Control and Signaling Circuits
- 03. 210.5 (C)(1) Identification of Ungrounded Conductors. Branch Circuits Supplied from One Nominal Voltage System.
- 04. 210.8 GFCI Protection. Exception (applicable to all installations)
- 05. 210.8(A)(3) Ground-Fault Circuit-Interrupter Protection for Personnel. Accessory Buildings.
- 06. 210.8(B) Exception 2. GFCI Protection for Personnel. Other than Dwellings.
- 07. 210.8(F) Exception No. 3 GFCI Protection for Personnel. Outdoor Outlets
- 08. 210.12(B) Exception No. 2. Arc-Fault Circuit-Interrupter Protection. Dwelling Units.
- 09. 210.12(E) Arc-Fault Circuit-Interrupter Protection. Branch Circuit Wiring Extensions, Modifications, or Replacements
- 10. 210.13(B) Ground-Fault Protection of Equipment. Solidly Grounded dc Electrical Systems
- 11. 210.23(A) Permissible Loads, Multiple-Outlet Branch Circuits. 10-Ampere Branch Circuits
- 12. 210.52(A)(5) Dwelling Unit Receptacle Outlets. Prohibited Locations (Countertops versus Wall Space)
- 13. 210.52(C)(4) Dwelling Unit Receptacle Outlets. Countertops and Work Surfaces. Prohibited Locations
- 14. 210.63 Branch Circuits. Equipment Requiring Servicing
- 15. 210.70 Lighting Outlets Required—Battery Operated Switches
- 16. 210.70 (A)(1) Lighting Outlets Required. Dwelling Units. Laundry Areas