This 16 hour package is designed to help Minnesota electricians renew their licenses. The courses in this package have been approved by the State of Minnesota and will count for a total of 16 hours. The package includes:

  • 1 A 2023 NEC Changes Chapters 1-2
  • 1 A 2023 NEC Changes Chapter 3
  • 1 A 2023 NEC Changes Chapters 5-6
  • 1 A 2023 NEC Changes Chapters 7-Annexes

IACET CEUs

This course gives you the opportunity to earn IACET CEUs through our parent company Certus. As an IACET Accredited Provider, Certus offers IACET CEUs for its learning events that comply with the ANSI/IACET Continuing Education and Training Standard. To earn IACET CEUs, you must:

  • Complete all lessons in the course,
  • Correctly answer every quiz question posed through the course,
  • Pass the final exam, and
  • Complete the course evaluation.

Assessment Information: This online course presents each section with commentary, a graphic illustration or photograph, and requires the learner to answer multiple choice questions after reviewing the content. The learner must complete all multiple-choice questions for each section correctly to get IACET CEUs, a certificate of completion, or state license renewal credit for the course. If the learner's first response is incorrect, learners will be immediately allowed to answer the question again until the correct answer is chosen. Question choices are randomized, so each participant will have a unique testing experience

Prerequisites: This course has no prerequisites.

Course Demonstration Video

Approved By: Department of Labor And Industry - Construction Codes and Licensing Division

  • 2023 NEC Changes Chapters 1-2
    • Chapters 1-2 - IACET Introduction
    • Chapter 1 [18 Activities]
      • 01. 100. Definitions. Scope.
      • 02. 100 Definitions. Class 4 Circuit, Class 4 Device, Class 4 Power System, Class 4 Receiver, Class 4 Transmitter, Class 4 Utilization Equipment.
      • 03. 100 Definitions. Counter (Countertop)
      • 04. 100 Definitions. Ground Fault Circuit Interrupter, Special Purpose.
      • 05. 100. Definitions. Ground-Fault Detector-Interrupter, dc (GFDI)
      • 06. 100 Grounding Conductor, Impedance.
      • 07. 100 Definitions. Grounded System, Impedance.
      • 08. 100 Definitions. Panelboard, Enclosed. (Enclosed Panelboard)
      • Additional Activities
        • 09. 100 Definitions. Restricted Industrial Establishment.
        • 10. 100 Definitions. Stored-Energy Power Supply System (SEPSS).
        • 11. 100 Definitions. Work Surface.
        • 12. 110.3(A)(8). Examination. Cybersecurity.
        • 13. 110.3(B) 110.3(B) Installation and Use.
        • 14. 110.16(B) Service Equipment and Feeder Supplied Equipment.
        • 15. 110.17. Servicing and Maintenance of Equipment.
        • 16. 110.20 Reconditioned Equipment.
        • 17. 110.26 Spaces About Electrical Equipment.
        • 18. 110.26(A)(6) Grade, Floor, or Working Platform.
    • Chapter 2 [49 Activities]
      • 01. Article 210, Branch Circuits Not Over 1000 Volts ac, 1500 Volts dc, Nominal.
      • 02. 210.2 Reconditioned Equipment
      • 03. 210.5(C)(1) Branch Circuits Supplied from More than One Nominal Voltage System.
      • 04. 210.8(A)(5) GFCI Protection for Personnel. Dwelling Units. Basements
      • 05. 210.8(A)(6) GFCI Protection for Personnel. Dwelling Units. Kitchens
      • 06. 210.8(A)(7) GFCI Protection for Personnel. Dwelling Units. Areas with Sinks
      • 07. 210.8(B). GFCI Protection for Personnel. Other Than Dwelling Units.
      • 08. 210.8(B) GFCI Protection for Personnel. Other Than Dwelling Units. Exceptions.
      • Additional Activities
        • 09. 210.8(D) GFCI Protection for Personnel. Specific Appliances.
        • 10. 210.8(F) GFCI Protection for Personnel. Outdoor Outlets
        • 11. 210.11(C)(4) Dwelling Units. Garage Branch Circuits.
        • 12. 210.12 Arc-Fault Circuit-Interrupter Protection
        • 13. 210.17 Guest Rooms and Guest Suites.
        • 14. 210.18. Branch-Circuit Ratings. Rating
        • 15. 210.23 Permissible Loads, Multiple-Outlet Branch Circuits.
        • 16. Table 210.24(1) Summary of Branch-Circuit Requirements - Copper Conductors.
        • 17. 210.52(A)(2). General Provisions. Wall Space.
        • 18. 210.52(C)(1). Countertops & Work Surfaces. Wall Spaces.
        • 19. 210.52(C)(2). Countertops & Work Surfaces. Island and Peninsular Countertops and Work Surfaces.
        • 20. 210.52(C)(3) Receptacle Outlet Location.
        • 21. 210.52(D) Bathrooms
        • 22. 210.70 Lighting Outlets Required.
        • 23. 210.70(A)(1) Dwelling Units. Habitable Rooms, Kitchens, Laundry Areas, and Bathrooms. Additional Locations
        • 24. 215.15 Barriers.
        • 25. 215.18 Surge Protection.
        • 26. 220.41 Dwelling Unit(s). Minimum Unit Load.
        • 27. 220.42 Lighting Load for Non-Dwelling Occupancies.
        • 28. 220.57 Electric Vehicle Supply Equipment (EVSE) Load.
        • 29. 220.110 Health Care Facilities. Receptacle Loads.
        • 30. 220.120 Marinas. Receptacle Loads.
        • 31. Article 225, Outside Branch Circuits and Feeders.
        • 32. 225.41 Emergency Disconnects
        • 33. 225.42. Surge Protection.
        • 34. 230.7 Other Conductors.
        • 35. 230.24(A) Clearances. Above Roofs.
        • 36. 230.30(B) Wiring Methods.
        • 37. 230.62(C) Barriers.
        • 38. 230.67. Surge Protection.
        • 39. 230.71(B) Two to Six Service Disconnecting Means.
        • 40. 230.85 Emergency Disconnects
        • 41. Article 235, Branch Circuits, Feeders, and Services Over 1000 Volts ac, 1500 Volts dc, Nominal.
        • 42. 240.4(B) Overcurrent Devices Rated 800?Amperes or Less
        • 43. 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers
        • 44. 242.9. Indicating
        • 45. Article 245, Overcurrent Protection for Systems Rated Over 1000 Volts ac, 1500 volts dc.
        • 46. 250.64(G) Enclosures with Ventilation Openings.
        • 47. 250.68(C) Grounding Electrode Conductor Connections.
        • 48. 250.118 Types of Equipment Grounding Conductors.
        • 49. 250.130 Equipment Grounding Conductor Connections.
    • Chapters 1-2 - Final Exam (21 questions)
  • 2023 NEC Changes Chapter 3
    • Chapter 3 - IACET Introduction
    • Chapter 3 [15 Activities]
      • 01. 300.4(E) Cables, Raceways, or Boxes Installed in or Under Metal-Corrugated Roof Decking.
      • 02. Table 300.5(A) Minimum Cover Requirements, 0 to 1000 Volts ac, 1500 Volts dc, Nominal.
      • 03. Article 305, General Requirements for Wiring Methods and Materials for Systems Rated Over 1000 volts ac, 1500 volts dc, Nominal.
      • 04. 310.15(B)(2). Rooftop.
      • 05. 312.10 Screws or Other Fasteners.
      • 06. 314.27(E) Weight-Supporting Ceiling Receptacles (WSCR) and Weight-Supporting Attachment Fittings (WSAF).
      • 07. 314.29(B) Underground.
      • 08. 334.10 Uses Permitted.
      • Additional Activities
        • 09. 334.15(B) Protection from Physical Damage.
        • 10. 334.40(B) Boxes and Fittings. Devices of Insulating Material.
        • 11. 344.28 Reaming and Threading.
        • 12. 352.10 Uses Permitted.
        • 13. 352.44 Expansion Fittings.
        • 14. Article 369, Insulated Bus Pipe (IBP)/Tubular Covered Conductors (TCC) Systems.
        • 15. Article 371, Flexible Bus Systems.
    • Chapter 3 - Final Exam (5 questions)
  • 2023 NEC Changes Chapters 5-6
    • Chapters 5-6 - IACET Introduction
    • Chapter 5 [29 Activities]
      • 01. 500.1 Hazardous (Classified) Locations, Classes I, II, and III, Divisions 1 and 2. Scope.
      • 02. 500.5(D) Class III Locations.
      • 03. 500.7 Protection Techniques.
      • 04. 500.8(E)(3) Unused Openings.
      • 05. 501.10(A)(2) Class I, Division 1. Flexible Connections
      • 06. 501.30(B) Bonding.
      • 07. 502.30(B)(1), 503.30(B)(1) Bonding.
      • 08. 503.10(A) Class III, Division 1.
      • Additional Activities
        • 09. 505.8 Protection Techniques.
        • 10. 505.15(C) Zone 2.
        • 11. 505.16(B) Zone 1.
        • 12. Article 512 Cannabis Oil Equipment and Cannabis Oil Systems Using Flammable Materials.
        • 13. 517.6 Patient Care-Related Electrical Equipment.
        • 14. 517.10(B). Not Covered.
        • 15. 517.14 Panelboard Bonding
        • 16. 517.20(A) Receptacles and Fixed Equipment.
        • 17. 517.22 Demand Factors.
        • 18. 517.30 Sources of Power.
        • 19. 517.70 Diagnostic Imaging and Treatment Equipment. Applicability.
        • 20. 518.5 Supply.
        • 21. 547.26 Physical Protection.
        • 22. 547.44 Equipotential Planes and Bonding of Equipotential Planes.
        • 23. 550.16(C)(1) Exposed Non-Current-Carrying Metal Parts
        • 24. 550.32. Service Equipment.
        • 25. 550.33(A) Feeder Equipment.
        • 26. 551.40(D). Loss of Ground Device.
        • 27. 555.14 Equipotential Planes and Bonding of Equipotential Planes.
        • 28. 555.15 Replacement of Equipment.
        • 29. 555.36(C) Emergency Electrical Disconnect.
    • Chapter 6 [21 Activities]
      • 01. 620.22 Branch Circuits for Car Lighting, Receptacle(s), Ventilation, Heating and Air-Conditioning.
      • 02. 620.23 Branch Circuits for Machine Room, Control Room/Machinery Space, Control Space, or Truss Interior Lighting and Receptacle(s).
      • 03. 625.40 Electric Vehicle Branch Circuit.
      • 04. 625.42 Rating.
      • 05. 625.43 Disconnecting Means.
      • 06. 626.1 Electrified Truck Parking Spaces. Scope.
      • 07. 630.8 Ground-Fault Circuit-Interrupter Protection for Personnel
      • 08. 646.19 Entrance to and Egress from Working Space.
      • Additional Activities
        • 09. 680.5 Ground-Fault Circuit-Interrupter (GFCI) and Special Purpose Ground-Fault Circuit-Interrupter (SPGFCI) Protection
        • 10. 680.12 Equipment Rooms, Vaults, and Pits.
        • 11. 680.21(D) Pool Pump Motor Replacement.
        • 12. 680.22(A) Receptacles.
        • 13. 680.26. Equipotential Bonding.
        • 14. 680.32 Ground-Fault Circuit-Interrupter (GFCI) and Special Purpose Ground-Fault Circuit Interrupter (SPGFCI) Protection Overview
        • 15. 680.43 Indoor Installations.
        • 16. 680.54(B),(C) Bonding, Equipotential Bonding of Splash Pads.
        • 17. 680.58 GFCI, SPGFCI Protection for Adjacent Receptacle Outlets.
        • 18. 680.59 GFCI and SPGFCI Protection for Permanently Installed Nonsubmersible Pumps.
        • 19. 680.83 Equipotential Bonding.
        • 20. 690.12(D) Buildings with Rapid Shutdown.
        • 21. 695.1. Fire Pumps. Scope.
    • Chapters 5-6 - Final Exam (16 questions)
  • 2023 NEC Changes Chapters 7-Annexes
    • Chapters 7-Annexes - IACET Introduction
    • Chapter 7 [14 Activities]
      • 01. 700.11 Wiring, Class-2 Powered Emergency Lighting Systems.
      • 02. 700.12(C) Supply Duration.
      • 03. 700.12(E) Stored-Energy Power Supply Systems (SEPSS).
      • 04. 701.1. Legally Required Standby Systems. Scope.
      • 05. 701.12(C)(3) Public Gas System, Municipal Water Supply.
      • 06. 702.7(A) Signs. Standby.
      • 07. 702.12(B). Portable Generators 15kW or Less.
      • 08. 705.10. Identification of Power Sources.
      • Additional Activities
        • 09. Article 724 Class 1 Power-Limited Circuits and Class 1 Power-Limited Remote-Control and Signaling Circuits.
        • 10. Article 725, Class 2 and Class 3 Power-Limited Circuits.
        • 11. Article 726 Class 4 Fault-Managed Power Systems
        • 12. 750.6. Listing
        • 13. 760.24(A) Mechanical Execution of Work.
        • 14. 760.33 Supply-Side Overvoltage Protection.
    • Chapter 8 [10 Activities]
      • 01. 800.3 Other Articles.
      • 02. 800.100(B)(2) Electrode. In Buildings or Structures with Grounding Means.
      • 03. 800.100(B)(3) Electrode. In Buildings or Structures Without an Intersystem Bonding Termination or Grounding Means.
      • 04. 800.113 Installation of Cables Used for Communication Circuits, Communications Wires, Cable Routing Assemblies, and Communications Raceways.
      • 05. 800.179 Wires and Cables.
      • 06. 810.15 Grounding or Bonding.
      • 07. 830.40(B). Low-Power Circuits.
      • 08. 830.47 Underground Network-Powered Broadband Communications Cables Entering Buildings.
      • 09. 830.133(C) Splicing of Medium-Powered Network-Powered Communications Cables.
      • 10. 830.160 Bends.
    • Chapter 9 and Annexes [1 Activities]
      • 01. Annex C, Table C.1 Conduit, Tubing, and Cable Tray Fill Tables for Conductors and Fixture Wires of the Same Size.
    • Chapters 7-Annexes - Final Exam (8 questions)
  • Course Completion
    • Mandatory Questionnaire
  • 2023 NEC Changes Chapters 1-2 Completion
    • Chapters 1-2 - Certificate of Completion
    • Chapters 1-2 - IACET Certificate of Completion
  • 2023 NEC Changes Chapter 3 Completion
    • Chapter 3 - Certificate of Completion
    • Chapter 3 - IACET Certificate of Completion
  • 2023 NEC Changes Chapters 5-6 Completion
    • Chapters 5-6 - Certificate of Completion
    • Chapters 5-6 - IACET Certificate of Completion
  • 2023 NEC Changes Chapters 7-Annexes Completion
    • Chapters 7-Annexes - Certificate of Completion
    • Chapters 7-Annexes - IACET Certificate of Completion
    • Expedited Reporting Available
Instructor Image

Instructor Bio

At Your Pace Online is a leader in the online education sphere. It offers thousands of hours of education in hundreds of markets and is approved in every state to offer professional continuing education.