Learn about electrical installation requirements for industrial and commercial applications with this eight-hour course. Stay compliant with highlighted 2023 National Electrical Code (NEC) changes.
Electricians in Montana who finish this course will be able to:
- Define “Accessible” as it relates to equipment.
- Explain why an equipment’s terminal temperature rating is used to select the conductor ampacity.
- List the general requirements for providing overcurrent protection to flexible bus systems.
- Identify the minimum value required for the interrupting rating of a circuit breaker.
- List the qualities that testing agencies check when examining electrical equipment.
- Describe when a feeder disconnect requires ground fault circuit interrupter (GFCI) protection.
- List the basic requirements for sizing outlet and device boxes.
- Identify when and how PVC, as a complete system, requires support.
- Identify when more than one motor is allowed on a branch circuit.
- List examples of continuous and non-continuous loads.
- Calculate the minimum ampacity required of a feeder tap.
- Describe the purpose of an effective ground-fault current path.
- Interpret Table 310.12 to size phase conductors for dwelling unit services.
- Understand the importance of using switches within their specified ratings and the types of permitted loads on switches.
- Describe the proper procedure for installing conductors in conduits.
- Identify where flexible cords are permitted to be used.
- Describe the level of detail required for circuit identification.
- Describe how overcurrent protection protects a motor control center (MCC).
- Identify when a motor must have a disconnecting means within sight of the motor.
- Identify installations or activities that require ground fault circuit interrupter (GFCI) protection for personnel.
- Calculate the minimum ampacity required of feeder supply conductors for an industrial machine.
Course ID(s): ELE-CE-CRS-00696
Approved By: Department of Labor and Industry - State Electrical Board
- Commercial and Industrial Wiring (2023 NEC)
- Introduction [6 Activities]
- 01. Introduction: 90.1 Scope.
- 02. 90.2 (A) Practical Safeguarding.
- 03. 90.2 (B) Adequacy.
- 04. 90.2 (C) Installations Covered.
- 05. 90.2 (D) Installations Not Covered.
- 06. 90.3 Code Arrangement.
- Definitions [10 Activities]
- 01. Definitions: Article 100 Definitions.
- 02. 100 Accessible (Readily Accessible).
- 03. 100 Branch Circuit.
- 04. 100 Continuous Load.
- 05. 100 Feeder.
- 06. 100 Grounded. Grounding.
- 07. 100 Ground-Fault Protection of Equipment.
- 08. 100 In Sight From (Within Sight From, Within Sight).
- 09. 100 Qualified Person.
- 10. 100 Separately Derived System.
- Requirements for Electrical Installations [14 Activities]
- 01. Requirements: 110.3 (A) Examination, Identification, Installation, and Use of Equipment.
- 02. 110.3 (B) Installation and Use.
- 03. 110.9 Interrupting Rating.
- 04. 110.14 (C) Electrical Connections - Temperature Limitations.
- 05. 110.14 (D) Terminal Connection Torque.
- 06. 110.18 Arcing Parts.
- 07. 110.22 Identification of Disconnecting Means.
- 08. 110.24 Available Fault Rating.
- View Additional Activities
- 09. 110.26 (A)(1)(2)(3) Depth, Width, and Height of Working Space.
- 10. 110.26 (C)(1) and (2) Large Equipment.
- 11. 110.26 (D) and (E) Illumination of Working Space and Dedicated Equipment Space.
- 12. Table 110.28 Enclosure Selection.
- 13. 110.33 Entrance to Enclosures and Access to Work Space.
- 14. 110.34 (A) Working Space.
- Branch Circuits [5 Activities]
- 01. Branch Circuits: 210.18 Rating.
- 02. 210.8 (B) Ground-Fault Circuit-Interrupter Protection for Personnel.
- 03. 210.19 Conductors ?? Minimum Ampacity and Size.
- 04. 210.21 Outlet Devices.
- 05. 210.63 Equipment Requiring Servicing.
- Feeders [2 Activities]
- 01. Feeders: 215.2 (A)(1) Feeders. Minimum Rating and Size.
- 02. 215.10 Ground-Fault Protection of Equipment.
- Outside Branch Circuits and Feeders [3 Activities]
- 01. Outside Branch Circuits and Feeders: 225.30 Number of Supplies.
- 02. 225.31 (A) and (B) Disconnecting Means.
- 03. 235.360 Clearances Over Roadways, Walkways, Rail, Water, and Open Land.
- Overcurrent Protection [4 Activities]
- 01. Overcurrent Protection: 240.6 Standard Ampere Ratings.
- 02. 240.21 (B) Feeder Taps.
- 03. 240.24 (A) Location in or on Premises. Accessibility.
- 04. 245.21 Circuit-Interrupting Devices.
- Grounding and Bonding [10 Activities]
- 01. Grounding and Bonding: 100 Ground-Fault Current Path, Effective (Effective Ground-Fault Current Path).
- 02. 250.30 (A) Grounding Separately Derived AC Systems, Grounded Systems.
- 03. 250.30 (B) and (C) Grounding Separately Derived AC Systems, Ungrounded Systems and Outdoor Source.
- 04. 250.32 Buildings or Structures Supplied by Feeder(s) or Branch Circuit(s).
- 05. 250.50 Grounding Electrode System.
- 06. 250.52 Grounding Electrodes.
- 07. 250.64 Grounding Electrode Conductor Installation.
- 08. 250.66 Size of Alternating-Current Grounding Electrode Conductor.
- 09. 250.118 Types of Equipment Grounding Conductors.
- 10. 250.122 (F) Size of Equipment Grounding Conductors in Parallel.
- Wiring Methods [4 Activities]
- 01. Wiring Methods: 300.3 (B) & 300.3(B)(1) Conductors of the Same Circuit & Paralleled Installations.
- 02. 300.4 (G) Insulated Fittings.
- 03. 300.5 (A) Minimum Cover Requirements.
- 04. 300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points.
- Conductors for General Wiring [3 Activities]
- 01. Conductors for General Wiring: 310.10 Uses Permitted (A) through (F).
- 02. 310.10 (G) Conductors in Parallel.
- 03. 310.12 Single-Phase Dwelling Service and Feeders.
- Outlet, Device, Pull, and Junction Boxes [3 Activities]
- 01. Outlet, Device, Pull and Junction Boxes: 314.24 Dimensions of Boxes.
- 02. 315.16 Marking for Type MV Cables and Conductors & 315.17 Marking for Type MV Cable Joints and Terminations.
- 03. 315.32 Uses Permitted for Type Medium Voltage Cables, Cable Joints, and Terminations.
- Conduit and Raceways [7 Activities]
- 01. Conduit and Raceways: 371.17 Overcurrent Protection of Flexible Bus Systems.
- 02. 371.18 Flexible Bus Systems Installation.
- 03. 314.16 Box Fill Calculations.
- 04. 398.15 Exposed Work.
- 05. 315.44 Shielding & 315.45 Shielding at Type MV Cable Joints and Terminations.
- 06. 352.10 Uses Permitted for Rigid Polyvinyl Chloride Conduits.
- 07. 352.44 Expansion Fittings.
- Switches and Receptacles [3 Activities]
- 01. Flexible Cords and Cables: 404.14 Rating and Use of Switches.
- 02. 406.3 Receptacle Rating and Type.
- 03. 406.4 (D) Receptacle Replacements.
- Switchboards and Panelboards [4 Activities]
- 01. Switchboards and Panelboards: 406.12 Tamper-Resistant Receptacles.
- 02. 424.93 Installation of Electric Radiant Heating Panels and Heating Panel Sets.
- 03. 410.10 Luminaires in Specific Locations.
- 04. 410.10 (A) through (F) Installation.
- Motors, Motor Circuits, and Controllers [12 Activities]
- 01. Motors, Motor Circuits, and Controllers: 430.6 Conductor Ampacity and Motor Rating Determination.
- 02. 430.7 Marking on Motors and Multimotor Equipment & 430.8 Marking on Controllers.
- 03. 430.22 Single Motor.
- 04. 430.24 Several Motors or a Motor(s) and Other Load(s).
- 05. 430.32 Continuous Duty Motors ?? Overload Protection.
- 06. 430.52 Rating or Setting for Individual Motor Circuit.
- 07. 430.53 Several Motors or Loads on One Branch Circuit.
- 08. 430.94 Overcurrent Protection.
- View Additional Activities
- 09. 430.102 (A) Disconnecting Means Location. Controller.
- 10. 430.102 (B) Disconnecting Means Location. Motor.
- 11. 430.107 Readily Accessible.
- 12. 430.109 Type.
- Generators [2 Activities]
- 01. Generators: 445.13 (A) Ampacity of Conductors. General. Conductor Ampacity.
- 02. 445.18 Disconnecting Means. 445.19 Emergency Shutdown of Prime Mover.
- Transformers [3 Activities]
- 01. Transformers: 450.1 Scope.
- 02. Table 450.3 (B) Maximum Rating of Overcurrent Protection for Transformers 1000 Volts and Less.
- 03. 450.13 (A)&(B) Accessibility. Open and Hollow Space Installations.
- Temporary Installations [2 Activities]
- 01. Temporary Wiring: 590.3 and 590.4 (D) Time Constraints. Receptacles.
- 02. 590.6 (A) (1) GFCI Protection for Personnel.
- Industrial Machinery [3 Activities]
- 01. Industrial Machinery: 670.3 Machine Nameplate Data.
- 02. 670.4 (A) Supply Conductors and Overcurrent Protection ?? Size.
- 03. 670.4 (B) & (C) Disconnecting Means and Overcurrent Protection.
- Introduction [6 Activities]
- Course Completion
- Mandatory Questionnaire
- Certificate of Completion
- Expedited Reporting Available