This 15-hour online program provides local electricians with a comprehensive review of the major changes introduced in the 2026 National Electrical Code (NEC), including new articles, revised definitions, and other updates that impact design, installation, and inspection practices across Chapters 1–9.
Learners will explore key revisions to:
- NEC terminology, code organization, equipment marking standards, and working-space provisions
- Branch-circuit, feeder, and service load calculations for dwelling units and EV supply equipment
- Grounded conductor identification, overcurrent protection methods, and systems operating above 1000 volts
- Conductor sizing, ampacity tables, cable routing methods, raceways, and physical protection standards
- Wiring devices, switches, panelboards, HVAC systems, generators, and stationary battery installations
- Hazardous occupancies, health care environments, marinas, swimming pools, elevators, and emergency power applications
- Communications infrastructure, limited-energy systems, broadband cable entry methods, and antenna safety practices
This training also covers the 2024 edition of NFPA 70E, focusing on electrical safety in the workplace by highlighting arc-flash protection, approach boundaries, and essential risk assessment procedures.
In addition, participants will review state-specific rules governing electrical licensure, disciplinary procedures, and common field concerns.
Course ID(s): 20-1338741
Approved By: Office of Professional Licensure and Certification - Board of Electricians
15 Hour Code Update: 2026 NEC Changes
Chapter 1 [33 Activities]
- 01. New Articles & Global Changes
- 02. 90.3 Code Arrangement.
- 03. 100 Definitions. Artificially Ventilated Room
- 04. 100 Definitions. Bonding Conductor, Grounding Electrode
- 05. 100 Definitions. Cable, Limited-Energy
- 06. 100 Definitions. Cannabis Oil Equipment and Systems
- 07. 100 Definitions. Ground-Fault Circuit Interrupter, Special Purpose (SPGFCI)
- 08. 100 Definitions. GFCI Special Purpose Classes C, D, and E
- 09. 100 Definitions. Hand Fastened
- 10. 100 Definitions. Lampholder
- 11. 100 Definitions. Service Point, Communications
- 12. 100 Definitions. Transformer Secondary Conductor
- 13. 100 Definitions. Wiring Device
- 14. 110.3(B) Examination and Installation of Equipment
- 15. 110.10 Available Fault Current
- 16. 110.15 High-Leg Marking
- 17. 110.16 Arc-Flash Hazard Marking
- 18. 110.17 Servicing of Equipment
- 19. 110.20 Reconditioned Equipment
- 20. 110.26 Spaces About Electrical Equipment
- 21. 110.26(A)(1) Depth of Working Space
- 22. 110.29 In Sight From
- 23. 110.31 Enclosures and Distance to Live Parts
- 24. 110.34 Work Space and Guarding
- 25. 110.39 In Sight From Over 1000V
- 26. 110.40 Electrical Connections Over 1000V
- 27. 110.75 Access to Manholes
- 28. 120 Branch-Circuit and Feeder Load Calculations
- 29. 120.41 Dwelling Units Minimum Unit Load
- 30. 120.57 EVSE Load
- 31. 120.82 Optional Feeder and Service Calculations
- 32. 120.83 Existing Dwelling Unit Calculations
- 33. 130 Energy Management Systems
Chapter 2 [28 Activities]
- 01. 200.7(A)(9) Identification of Grounded Conductors
- 02. 206 Non-Power-Limited Remote-Control Circuits
- 03. 210.5(C)(1) Identification of Ungrounded Conductors
- 04. 210.8 GFCI Protection Exception
- 05. 210.8(A)(3) GFCI Protection Accessory Buildings
- 06. 210.8(B) Exception GFCI Other Than Dwellings
- 07. 210.8(F) Exception Outdoor Outlets
- 08. 210.12(B) Exception AFCI Dwelling Units
- 09. 210.12(E) AFCI Circuit Extensions
- 10. 210.13(B) Ground-Fault Protection of Equipment
- 11. 210.23(A) Permissible Loads
- 12. 210.52(A)(5) Receptacle Prohibited Locations
- 13. 210.52(C)(4) Countertop Receptacles
- 14. 210.63 Equipment Requiring Servicing
- 15. 210.70 Lighting Outlets Battery Switches
- 16. 210.70(A)(1) Laundry Lighting Outlets
- 17. 225.31 Disconnecting Means
- 18. 230.62(C) Service Equipment Barriers
- 19. 230.68 Meter Socket Exception
- 20. 230.70 Service Disconnects
- 21. 240.7 Overcurrent Protective Devices
- 22. 240.24(E) Not Located in Bathrooms
- 23. 245.6 Overcurrent Protection Over 1000V
- 24. 250.122(H) Equipment Grounding Conductors
- 25. 265 Branch Circuits Over 1000V
- 26. 266 Feeders Over 1000V
- 27. 268 Services Over 1000V
- 28. 270 Grounding and Bonding Over 1000V
Chapter 3 [32 Activities]
- 01. 300.1 General Requirements Scope
- 02. 300.4(C) Damaged Conductors
- 03. 300.6(E) Protection Against Physical Damage
- 04. 300.7(D)(3) Underground Installation Protection
- 05. 300.9 Raceways Different Temperatures
- 06. 300.13(B) Securing Above Ceilings
- 07. 300.13(E) Cable Ties Support
- 08. 300.19(B) Conductors in Raceway
- 09. 300.24 Bends
- 10. 300.25(C)(1) Wiring in Ducts
- 11. Article 305 Wiring Methods Over 1000V
- 12. 310.4 Conductor Construction
- 13. 310.5(A) Minimum Size Part I
- 14. 310.5(A) Minimum Size Part II
- 15. 310.6(B) Conductor Identification
- 16. 310.10(D)(3) Sunlight Exposure
- 17. 310.12 Dwelling Services
- 18. 310.14(A)(2) Ampacity Selection
- 19. 310.15(C)(1) Adjustment Factors
- 20. 310.16 Ampacities
- 21. 312.11(A)(5) Enclosures and Splices
- 22. 314.23(E)(F) Raceway Enclosures
- 23. 334.10 NM Cable Uses Permitted
- 24. 334.12 NM Cable Uses Not Permitted
- 25. 334.24 NM Cable Bending
- 26. 334.30 NM Cable Support
- 27. 334.104 NM Cable Construction
- 28. 336.30 Tray Cable Support
- 29. 344.10 RMC Uses Permitted
- 30. 344.29 RMC Terminations
- 31. 350.10(5) LFMC Uses Permitted
- 32. 352.20(B) PVC Conduit Maximum Size
Chapter 4 [23 Activities]
- 01. 402.5 Fixture Wire Ampacities
- 02. 404.1 Switches Scope
- 03. 406.1 Wiring Devices Scope
- 04. 406.12(D)(3) Replacement GFCI
- 05. 406.14(G)(3) Orientation
- 06. 406.40 Wiring Devices General Use
- 07. 406.40(D) Faceplates and USB
- 08. 408.6 Switchboards Rating
- 09. 408.10 Identification
- 10. 409.23 Panel Supply
- 11. 422.12 Heating Equipment
- 12. 424.2 Listing Requirements
- 13. 424.3 Reconditioned Equipment
- 14. 426 Pavement Heating
- 15. 430.22(H) Motors Design
- 16. 430.24 Motors Exception
- 17. 440.2 AC Listing
- 18. 440.4(A) Nameplate
- 19. 440.14 Location
- 20. 440.15 Identification
- 21. 445.13 Generators
- 22. 480.2 Batteries Listing
- 23. 480.8 Grounding
Chapter 5 [18 Activities]
- 01. Chapter 5 Title Change
- 02. 500.5(D)(1) Class III Locations
- 03. 500.7 Protection Techniques
- 04. 500.30 Bonding
- 05. 501.3 Reconditioned Equipment
- 06. 505.8(Q) Protection Techniques
- 07. 511.10(B)(3) Garages EV
- 08. 512.3 Cannabis Oil Systems
- 09. 512.6 Prohibited Locations
- 10. 514.11 Fuel Disconnects
- 11. 517.4 Health Care Service
- 12. 517.20(A)(3) Wet Locations
- 13. 517.42 Coordination
- 14. 517.43(A)(7) Life Safety Branch
- 15. 551.32 RV Inverters
- 16. 551.40(D) GMI
- 17. 555.9 Marinas Design
- 18. 555.35(F) Testing
Chapter 6 [32 Activities]
- 01. 600 Chapter 6 Title Change
- 02. 600.6(A)(2) Signs Disconnects
- 03. 604.100 Wiring Systems
- 04. 610.4 Cranes
- 05. 620.21(A)(1) Elevators
- 06. 620.21(A)(3) Machine Rooms
- 07. 620.22(A)(1) Lighting Circuits
- 08. 620.51(A) Disconnects
- 09. 620.51(E) Surge Protection
- 10. 620.62 Coordination
- 11. 624 Vehicle Systems
- 12. 625.4 Qualified Person
- 13. 625.5 Markings
- 14. 625.17 Cord
- 15. 625.43 Disconnect
- 16. 625.44 Connection
- 17. 626.32 Truck Power
- 18. 645.27 IT Coordination
- 19. 680.5(B) Pools Protection
- 20. 680.12(B) Equipment Rooms
- 21. 680.14 Corrosion
- 22. 680.21(D) Motors
- 23. 680.22(D) Equipment
- 24. 680.23 Underwater Lights
- 25. 680.26 Bonding
- 26. 680.30 Additional Rules
- 27. 690.7 PV Voltage
- 28. 690.31 Conductors
- 29. 690.43 Grounding
- 30. 695.7 Fire Pumps
- 31. 695.14 Generator Wiring
- 32. Additional Systems Coverage
Chapter 7 [19 Activities]
- 01. 700 Chapter 7 Title Change
- 02. 700.1 Scope
- 03. 700.4 Commissioning
- 04. 700.4(F) Temporary Power
- 05. 700.6 Bypass
- 06. 700.10 Wiring
- 07. 700.11 Lighting
- 08. 700.12 Luminaires
- 09. 700.24 Controls
- 10. 701.4 Standby Systems
- 11. 701.6 Bypass
- 12. 701.9 Surge
- 13. 701.12 Generators
- 14. 722 Limited Energy
- 15. 723 Cable Routing
- 16. System Integration
- 17. Field Applications
- 18. Maintenance Considerations
- 19. Compliance Review
Chapter 8 [8 Activities]
- 01. 800.1 Scope
- 02. 800.2 Listing
- 03. 800.44 Overhead
- 04. 800.47 Underground
- 05. 800.48 Unlisted
- 06. 810.13 Antenna
- 07. 830.2 Broadband
- 08. 830.47 Underground Broadband
Chapter 9 and Annexes [6 Activities]
- 01. Chapter 9 Table 13
- 02. Annex A References
- 03. Annex B Cable Shield
- 04. Annex D Example D14
- 05. Annex D Example D15
- 06. Annex L Future NEC
Electrical Safety (NFPA 70E 2024) [12 Activities]
- 01. Different Code Purpose
- 02. Core Principles
- 03. Safe Work Condition
- 04. Working Energized
- 05. Arc Flash PPE
- 06. Approach Boundaries
- 07. Risk Assessment
- 08. Maintenance and Training
- 09. Chapters 2 and 3 Overview
- 10. Field Scenarios
- 11. Common Violations
- 12. Big Picture
New Hampshire Laws and Rules [13 Activities]
- 01. Definitions
- 02. Apprentice Supervision
- 03. Disciplinary Action
- 04. License Renewal
- 05. License Lapse
- 06. Continuing Education
- 07. General Administration
- 08. Equipment and Wiring Use
- 09. Physical Protection
- 10. Working Clearance
- 11. Disconnecting Means
- 12. Emergency Lighting
- 13. Sealing and Protection
Course Completion
Mandatory Questionnaire
Certificate of Completion

