This 10-hour package is approved for Delaware electricians. This package includes:

  • 2023 NEC Changes Part 1
  • 2023 NEC Changes Part 2

Learning Objectives:

  • Describe the overall layout of the National Electrical Code and the addition of new articles.
  • Identify the scope of what is covered and not covered in the Code.
  • List which chapters can supplement or modify other chapters.
  • Identify updates, additions, and changes to Chapter 1 of the 2023 National Electrical Code.
  • Describe changes in the way terms are presented in Article 100, Definitions.
  • Define 12 terms that are newly defined in the 2023 NEC.
  • Outline changes to the general requirements for electrical installations found in Chapter 110 of the 2023 NEC.
  • Identify updates, additions, and changes to Chapter 2 of the 2023 National Electrical Code.
  • Describe changes for branch circuits found in Chapter 2 of the 2023 NEC.
  • Identify changes to branch-circuit requirements as summarized in Tables 210.24(1) and 210.24(2).
  • Outline new requirements covering barriers and surge protection for feeders found in Chapter 2 of the 2023 NEC.
  • Identify changes to branch-circuit, feeder, and service load calculations found in Chapter 2 of the 2023 NEC.
  • Identify updates, additions, and changes to Chapter 2 of the 2023 National Electrical Code.
  • Describe changes for branch circuits found in Chapter 2 of the 2023 NEC.
  • Outline new requirements covering barriers and surge protection for feeders found in Chapter 2 of the 2023 NEC.
  • Describe changes to emergency disconnects and surge protection for outside branch circuits and feeders found in Chapter 2 of the 2023 NEC.
  • Outline the new wiring method for installing underground service conductors.
  • List the locations that must be provided with surge protection devices.
  • Identify changes for service conductors and service installation requirements found in Chapter 2 of the 2023 NEC.
  • Outline the new declaration regarding standard overcurrent device ratings found in Chapter 2 of the 2023 NEC.
  • Identify changes to the standard ampere ratings in Table 240.6(A).
  • Describe the new requirement that surge protection devices indicate they are functioning properly.
  • Summarize the new requirements for overcurrent protection requirements for systems over 1000 volts ac, 1500 volts dc in Article 245.
  • Identify the new requirements for grounding and bonding in Chapter 2 of the 2023 NEC.
  • Identify updates, additions, and changes to Chapter 3 of the 2023 National Electrical Code.
  • Summarize the general requirements for wiring methods and materials for systems rated over 1000 volts ac, 1500 volts dc covered in Article 305.
  • Describe changes and additions to the exceptions for cables, raceways, or boxes installed in or under metal-corrugated roof decking found in Chapter 3 of the 2023 NEC.
  • Outline new requirements for installing screws and other fasteners in cabinets, cutout boxes, and meter socket enclosures found in Chapter 3 of the 2023 NEC.
  • Identify additions and changes to requirements for outlet boxes, underground boxes, and handhole enclosures found in Chapter 3 of the 2023 NEC.
  • Outline new requirements for insulated bus pipe and flexible bus systems found in Chapter 3 of the 2023 NEC.
  • List changes to uses permitted and not permitted for nonmetallic-sheathed cable.
  • Identify changed requirements for use and installation of rigid polyvinyl chloride conduit (PVC) found in Chapter 3 of the 2023 NEC.
  • Outline new requirements for receptacles, cord connectors, and attachment plugs found in Chapter 4 of the 2023 NEC.
  • Describe new requirements for switchboards, switchgear, and panelboards found in Chapter 4 of the 2023 NEC.

Approved By: Board of Electrical Examiners

  • 2023 NEC Changes Part 1
    • Chapter 1 [22 Activities]
      • 01. 100. Definitions. Scope.
      • 02. 100 Definitions. Attachment Fitting, Weight-Supporting (WSAF). & Receptacle, Weight-Supporting Ceiling (WSCR).
      • 03. 100 Definitions. Class 4 Circuit, Class 4 Device, Class 4 Power System, Class 4 Receiver, Class 4 Transmitter, Class 4 Utilization Equipment.
      • 04. 100 Definitions. Cord Connector.
      • 05. 100 Definitions. Counter (Countertop)
      • 06. 100 Definitions. Ground Fault Circuit Interrupter, Special Purpose.
      • 07. 100. Definitions. Ground-Fault Detector-Interrupter, dc (GFDI)
      • 08. 100 Grounding Conductor, Impedance.
      • View Additional Activities
        • 09. 100 Definitions. Grounded System, Impedance.
        • 10. 100 Definitions. Panelboard, Enclosed. ??(Enclosed Panelboard)
        • 11. 100 Definitions. Restricted Industrial Establishment.
        • 12. 100 Definitions. Stored-Energy Power Supply System (SEPSS).
        • 13. 100 Definitions. Work Surface.
        • 14. 110.3(A)(8). Examination. Cybersecurity.
        • 15. 110.3(B) 110.3(B) Installation and Use.
        • 16. 110.16(B) Service Equipment and Feeder Supplied Equipment.
        • 17. 110.17. Servicing and Maintenance of Equipment.
        • 18. 110.20 Reconditioned Equipment.
        • 19. 110.26 Spaces About Electrical Equipment.
        • 20. 110.26(A)(6) Grade, Floor, or Working Platform.
        • 21. 110.29 In Sight From (Within Sight From, Within Sight)
        • 22. 110.33(A) Entrance to Enclosures and Access to Working Space. Entrance.
    • Chapter 2, Part 1 [28 Activities]
      • 01. Article 210, Branch Circuits Not Over 1000 Volts ac, 1500 Volts dc, Nominal.
      • 02. 210.2 Reconditioned Equipment
      • 03. 210.5(C)(1) Branch Circuits Supplied from More than One Nominal Voltage System.
      • 04. 210.8(A)(5) GFCI Protection for Personnel. Dwelling Units. Basements
      • 05. 210.8(A)(6) GFCI Protection for Personnel. Dwelling Units. Kitchens
      • 06. 210.8(A)(7) GFCI Protection for Personnel. Dwelling Units. Areas with Sinks
      • 07. 210.8(B). GFCI Protection for Personnel. Other Than Dwelling Units.
      • 08. 210.8(B) GFCI Protection for Personnel. Other Than Dwelling Units. Exceptions.
      • View Additional Activities
        • 09. 210.8(D) GFCI Protection for Personnel. Specific Appliances.
        • 10. 210.8(F) GFCI Protection for Personnel. Outdoor Outlets
        • 11. 210.11(C)(4) Dwelling Units. Garage Branch Circuits.
        • 12. 210.12 Arc-Fault Circuit-Interrupter Protection
        • 13. 210.17 Guest Rooms and Guest Suites.
        • 14. 210.18. Branch-Circuit Ratings. Rating
        • 15. 210.23 Permissible Loads, Multiple-Outlet Branch Circuits.
        • 16. Table 210.24(1) Summary of Branch-Circuit Requirements - Copper Conductors.
        • 17. 210.52(A)(2). General Provisions. Wall Space.
        • 18. 210.52(C)(1). Countertops & Work Surfaces. Wall Spaces.
        • 19. 210.52(C)(2). Countertops & Work Surfaces. Island and Peninsular Countertops and Work Surfaces.
        • 20. 210.52(C)(3) Receptacle Outlet Location.
        • 21. 210.52(D) Bathrooms
        • 22. 210.70 Lighting Outlets Required.
        • 23. 210.70(A)(1) Dwelling Units. Habitable Rooms, Kitchens, Laundry Areas, and Bathrooms. Additional Locations
        • 24. 215.15 Barriers.
        • 25. 215.18 Surge Protection.
        • 26. 220.41 Dwelling Unit(s). Minimum Unit Load.
        • 27. 220.42 Lighting Load for Non-Dwelling Occupancies.
        • 28. 220.57 Electric Vehicle Supply Equipment (EVSE) Load.
  • 2023 NEC Changes Part 2
    • Chapter 2, Part 2 [25 Activities]
      • 01. 220.110 Health Care Facilities. Receptacle Loads.
      • 02. 220.120 Marinas. Receptacle Loads.
      • 03. Article 225, Outside Branch Circuits and Feeders.
      • 04. 225.41 Emergency Disconnects
      • 05. 225.42. Surge Protection.
      • 06. 230.7 Other Conductors.
      • 07. 230.24(A) Clearances. Above Roofs.
      • 08. 230.30(B) Wiring Methods.
      • View Additional Activities
        • 09. 230.62(C) Barriers.
        • 10. 230.67. Surge Protection.
        • 11. 230.71(B) Two to Six Service Disconnecting Means.
        • 12. 230.85 Emergency Disconnects
        • 13. Article 235, Branch Circuits, Feeders, and Services Over 1000 Volts ac, 1500 Volts dc, Nominal.
        • 14. 240.4(B) Overcurrent Devices Rated 800?Amperes or Less
        • 15. 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers
        • 16. 242.9. Indicating
        • 17. Article 245, Overcurrent Protection for Systems Rated Over 1000 Volts ac, 1500 volts dc.
        • 18. 250.64(G) Enclosures with Ventilation Openings.
        • 19. 250.68(C) Grounding Electrode Conductor Connections.
        • 20. 250.118 Types of Equipment Grounding Conductors.
        • 21. 250.130 Equipment Grounding Conductor Connections.
        • 22. 250.130(C) Replacement of Nongrounding Receptacle or Snap Switch and Branch Circuit Extensions.
        • 23. 250.140 Frames of Ranges and Clothes Dryers.
        • 24. 250.148 Continuity of Equipment Grounding Conductors and Attachment in Boxes.
        • 25. 250.186 Grounding Service-Supplied Alternating-Current Systems.
    • Chapter 3 [15 Activities]
      • 01. 300.4(E) Cables, Raceways, or Boxes Installed in or Under Metal-Corrugated Roof Decking.
      • 02. Table 300.5(A) Minimum Cover Requirements, 0 to 1000 Volts ac, 1500 Volts dc, Nominal.
      • 03. Article 305, General Requirements for Wiring Methods and Materials for Systems Rated Over 1000 volts ac, 1500 volts dc, Nominal.
      • 04. 310.15(B)(2). Rooftop.
      • 05. 312.10 Screws or Other Fasteners.
      • 06. 314.27(E) Weight-Supporting Ceiling Receptacles (WSCR) and Weight-Supporting Attachment Fittings (WSAF).
      • 07. 314.29(B) Underground.
      • 08. 334.10 Uses Permitted.
      • View Additional Activities
        • 09. 334.15(B) Protection from Physical Damage.
        • 10. 334.40(B) Boxes and Fittings. Devices of Insulating Material.
        • 11. 344.28 Reaming and Threading.
        • 12. 352.10 Uses Permitted.
        • 13. 352.44 Expansion Fittings.
        • 14. Article 369, Insulated Bus Pipe (IBP)/Tubular Covered Conductors (TCC) Systems.
        • 15. Article 371, Flexible Bus Systems.
    • Chapter 4 [10 Activities]
      • 01. 404.1 Switches. Scope.
      • 02. 404.2(C) Switches Controlling Lighting Loads.
      • 03. 404.14(D) Snap Switch Terminations.
      • 04. 404.16 Reconditioned Equipment
      • 05. 404.30 Switch Enclosures with Doors.
      • 06. 406.3(D) Receptacle Terminations.
      • 07. 406.4(G). Protection of Floor Receptacles.
      • 08. 406.6(D) Receptacle Faceplate (Cover Plates) with Integral Night Light and/or USB Charger.
      • 09. 406.9(A),(B) Damp Locations, Wet Locations.
      • 10. 406.9(C) Bathtub and Shower Space.
  • Course Completion
    • Mandatory Questionnaire
    • 2023 NEC Changes Part 1 - Certificate of Completion (1 of 2)
    • 2023 NEC Changes Part 2 - Certificate of Completion (2 of 2)
Instructor Image

Instructor Bio

At Your Pace Online is a leader in the online education sphere. It offers thousands of hours of education in hundreds of markets and is approved in every state to offer professional continuing education.