After completing this Maryland-approved course, the participant will be able to apply 50 important changes to the 2023 National Electrical Code in common wiring practice.
Learning Objectives:
- Outline the new declaration regarding standard overcurrent device ratings found in Chapter 2 of the 2023 NEC.
- Identify changes to the standard ampere ratings in Table 240.6(A).
- Describe the new requirement that surge protection devices indicate they are functioning properly.
- Summarize the new requirements for overcurrent protection requirements for systems over 1000 volts ac, 1500 volts dc in Article 245.
- Identify the new requirements for grounding and bonding in Chapter 2 of the 2023 NEC.
- Identify updates, additions, and changes to Chapter 3 of the 2023 National Electrical Code.
- Summarize the general requirements for wiring methods and materials for systems rated over 1000 volts ac, 1500 volts dc covered in Article 305.
- Describe changes and additions to the exceptions for cables, raceways, or boxes installed in or under metal-corrugated roof decking found in Chapter 3 of the 2023 NEC.
- Outline new requirements for installing screws and other fasteners in cabinets, cutout boxes, and meter socket enclosures found in Chapter 3 of the 2023 NEC.
- Identify additions and changes to requirements for outlet boxes, underground boxes, and handhole enclosures found in Chapter 3 of the 2023 NEC.
- Outline new requirements for insulated bus pipe and flexible bus systems found in Chapter 3 of the 2023 NEC.
- List changes to uses permitted and not permitted for nonmetallic-sheathed cable.
- Identify changed requirements for use and installation of rigid polyvinyl chloride conduit (PVC) found in Chapter 3 of the 2023 NEC.
- Identify updates, additions, and changes to Chapter 4 of the 2023 National Electrical Code.
- Describe the change in scope to Chapter 4 of the 2023 NEC.
Approved By: State Board of Electricians
- 2023 NEC Changes Part 2
- Chapter 2 [25 Activities]
- 01. 220.110 Health Care Facilities. Receptacle Loads.
- 02. 220.120 Marinas. Receptacle Loads.
- 03. Article 225, Outside Branch Circuits and Feeders.
- 04. 225.41 Emergency Disconnects
- 05. 225.42. Surge Protection.
- 06. 230.7 Other Conductors.
- 07. 230.24(A) Clearances. Above Roofs.
- 08. 230.30(B) Wiring Methods.
- Additional Activities
- 09. 230.62(C) Barriers.
- 10. 230.67. Surge Protection.
- 11. 230.71(B) Two to Six Service Disconnecting Means.
- 12. 230.85 Emergency Disconnects
- 13. Article 235, Branch Circuits, Feeders, and Services Over 1000 Volts ac, 1500 Volts dc, Nominal.
- 14. 240.4(B) Overcurrent Devices Rated 800 Amperes or Less
- 15. 240.6(A) Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers
- 16. 242.9. Indicating
- 17. Article 245, Overcurrent Protection for Systems Rated Over 1000 Volts ac, 1500 volts dc.
- 18. 250.64(G) Enclosures with Ventilation Openings.
- 19. 250.68(C) Grounding Electrode Conductor Connections.
- 20. 250.118 Types of Equipment Grounding Conductors.
- 21. 250.130 Equipment Grounding Conductor Connections.
- 22. 250.130(C) Replacement of Nongrounding Receptacle or Snap Switch and Branch Circuit Extensions.
- 23. 250.140 Frames of Ranges and Clothes Dryers.
- 24. 250.148 Continuity of Equipment Grounding Conductors and Attachment in Boxes.
- 25. 250.186 Grounding Service-Supplied Alternating-Current Systems.
- Chapter 3 [15 Activities]
- 01. 300.4(E) Cables, Raceways, or Boxes Installed in or Under Metal-Corrugated Roof Decking.
- 02. Table 300.5(A) Minimum Cover Requirements, 0 to 1000 Volts ac, 1500 Volts dc, Nominal.
- 03. Article 305, General Requirements for Wiring Methods and Materials for Systems Rated Over 1000 volts ac, 1500 volts dc, Nominal.
- 04. 310.15(B)(2). Rooftop.
- 05. 312.10 Screws or Other Fasteners.
- 06. 314.27(E) Weight-Supporting Ceiling Receptacles (WSCR) and Weight-Supporting Attachment Fittings (WSAF).
- 07. 314.29(B) Underground.
- 08. 334.10 Uses Permitted.
- Additional Activities
- 09. 334.15(B) Protection from Physical Damage.
- 10. 334.40(B) Boxes and Fittings. Devices of Insulating Material.
- 11. 344.28 Reaming and Threading.
- 12. 352.10 Uses Permitted.
- 13. 352.44 Expansion Fittings.
- 14. Article 369, Insulated Bus Pipe (IBP)/Tubular Covered Conductors (TCC) Systems.
- 15. Article 371, Flexible Bus Systems.
- Chapter 4 [10 Activities]
- 01. 404.1 Switches. Scope.
- 02. 404.2(C) Switches Controlling Lighting Loads.
- 03. 404.14(D) Snap Switch Terminations.
- 04. 404.16 Reconditioned Equipment
- 05. 404.30 Switch Enclosures with Doors.
- 06. 406.3(D) Receptacle Terminations.
- 07. 406.4(G). Protection of Floor Receptacles.
- 08. 406.6(D) Receptacle Faceplate (Cover Plates) with Integral Night Light and/or USB Charger.
- 09. 406.9(A),(B) Damp Locations, Wet Locations.
- 10. 406.9(C) Bathtub and Shower Space.
- Chapter 2 [25 Activities]
- Course Completion
- Mandatory Questionnaire
- Certificate of Completion